User manual ASCOM AUTROSAFE 4 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ASCOM AUTROSAFE 4. We hope that this ASCOM AUTROSAFE 4 user guide will be useful to you.


ASCOM AUTROSAFE 4 BROCHURE: Download the complete user guide (2955 Ko)

Manual abstract: user guide ASCOM AUTROSAFE 4BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Autronica Fire and Security launched AutroSafe, our high-end fire detection system, in 1999. From day one, AutroSafe has proven its unique stability and reliability in more than 15 000 installations worldwide, both on- and offshore. AutroSafe 4 provides advanced functionality for a wide range of applications. [. . . ] AutroSafe SelfVerify® solves all issues The necessity of reducing high maintenance of manual maintenance, leaving time costs and increasing fire security, encouraged consuming and costly physical testing no Autronica to invest considerable time and longer necessary. With AutroSafe SelfVerify®, effort in developing this unique technology. the system checks all Over the last decade it detectors, interfaces, has proven its worth in "Quite possibly the safest connections and cables over 15 000 applications ­ from detector chamber to in onshore, offshore and and most reliable fire safety alarm output ­ every single maritime installations. optimal detection" The self-testing system Not only does the system Most fire detection systems test whether a detector is capable of provoking depend on costly and often irregular manual an alarm, it even verifies the sensitivity of inspections, which involve a number of every detector with a calibrated signal. The challenges and problems: SelfVerify system ensures that each detector Detectors may be out of reach always responds to the correct alarm level. In the event of irregularities, the display on the Service engineers may not have access operating panel will accurately pinpoint the to particular areas source of any problem. Manual testing with gas or smoke is not reliable Test gas or smoke is rarely used in calibrated quantities Even a faulty detector will eventually react if its chamber is filled with enough smoke manual tests of detectors, leaving damaged detectors unnoticed for far too long AutroSafe SelfVerify® is developed for worldwide standards and regulations, and the detectors are certified according to European directives (CPD) requiring EN 54 compliance. AutroSafe SelfVerify® ensures that you have the safest and most reliable fire safety system available ­ a system ensuring optimal detection. Excessive and irregular intervals between 6n mORE REliAblE mAinTEnAncE. minimUm dOwnTimE. ThE nEw AUTROSAFE 4 ­ one point access AutroSafe 4 is managed through a single point of operation for download of configuration data or program upgrades. This ensures a faster and safer way to change or upgrade the system program, using the panel network, AutroNet or a USB memory stick. Minimum downtime, through quick and easy commissioning. lARgE cAPAciTy ­ without compromising security Our Ethernet-based panel network, AutroNet, connects the different panels through a high-speed (100Mbps) redundant system. Delivering solid, reliable performance in line with current regulations. 64 fire alarm panels 15 000 loop units connected to one system 6 detector loops per panel 127 loop units connected to one detector loop 15 loop units connected to one PowerLoop 31 loop units connected to AutroField Bus Event log with up to 10 000 events Up to 3 600m n9 inTEgRATEd 3Rd PARTy inTERFAcE ­ granting unlimited communication options AutroSafe 4 communicates with equipment using the following protocols ESPA 4. 4. 4 ­ allowing connectivity with devices such as AutroTel alarm routing via telephone networks and pocket paging systems Voyage Data Recorder (VDR) NMEA-0183 ­ allowing connectivity with devices such as the maritime MODBUS ­ allowing connectivity with Programmable Logic Controllers (PLC) AutroCom ­ allowing interface to control and monitoring systems (AutroMaster) AutroSafe 4 includes the following communication ports 2 Ethernet ports for AutroNet, AutroCom and configuration data/system software upgrade 1 AL_Com+ port (interfacing loop drivers and I/O units) 1 RS-232, RS-422 or RS-485 (AutroCom/ESPA4. 4. 4/MODBUS/VDR) 1 AutroFieldBus interface 2 USB host ports for printer/USB memory stick (configuration data and system software upgrade) FailSafe relay output clEAn dESign And PERFORmAncE ­ balancing intuitive user interface with high technology During normal operation, the power indicator will always display a steady green light when the power is ON. No disrupting or unnecessary information is shown, only indicators relevant to the actual condition are visible. imPROvEd FlExibiliTy ­ adjustable to any environment You can change multi detector operation class, adjust a single detector or a group of detectors or operate class switch for a period of time. PROvEn lOOP UniTS ­ a wide range for any application All types and series of AutroSafe detectors, manual call points, I/O units and sounders can operate on the same detection loop. 10 n inTROdUcing AUTROnET ­ a new standard in reliable data and information transmission To provide maximum dependability, Autronica has developed AutroNet ­ a dual path transmission network based on a high-bandwidth Ethernet network (100Mbps) suitable for safety-critical systems. AutroNet secures the transmission of data and information even if a line fault (break, switch port fault etc. ) is present. Any alarms are transmitted safely to all panels because all network traffic is duplicated along two independent network paths. The unique combination of AutroNet and AutroSafe results in a flexible and reliable system which is easy to maintain, modify and expand. "Flexible and reliable ­ easy to maintain and expand" 12 n dUAl PATh. TwicE AS SEcURE. ­ making sure you're in control AUTROmASTER iSEmS AutroMaster ISEMS is an Integrated Safety and Emergency Management System combining the strengths of a powerful fire detection system with control and monitoring functions dedicated to make sure you are in control in case of an emergency. Graphical user interface The AutroMaster provides an intuitive control and monitoring interface built to save valuable time when every second counts. [. . . ] The AutroSafe OPC server provides a standard OPC interface for the AutroSafe integrated fire detection system. OPC (OLE for Process Control) is a software standard issued by Windowsbased applications to access data from process control systems. The basic principle of OPC is that OPC client applications communicate with an OPC server via a standardized, open and vendor-independent interface. n 15 AUTROnicA FiRE And SEcURiTy ­ a leading innovator of safety Autronica Fire and Security is a leading innovator, manufacturer and supplier of fire safety equipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ASCOM AUTROSAFE 4




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ASCOM AUTROSAFE 4 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.