User manual ASROCK K8UPGRADE-NF3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ASROCK K8UPGRADE-NF3. We hope that this ASROCK K8UPGRADE-NF3 user guide will be useful to you.


ASROCK K8UPGRADE-NF3 : Download the complete user guide (400 Ko)

You may also download the following manuals related to this product:

   ASROCK K8UPGRADE-NF3 INSTALLATION (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (837 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (822 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION (1324 ko)
   ASROCK K8UPGRADE-NF3 INSTALLATION GUIDE (1324 ko)

Manual abstract: user guide ASROCK K8UPGRADE-NF3

Detailed instructions for use are in the User's Guide.

[. . . ] K8Upgrade-NF3 User Manual Version 1. 1 Published July 2006 Copyright©2006 ASRock INC. All rights reserved. 1 Copyright Notice: No part of this manual may be reproduced, transcribed, transmitted, or translated in any language, in any form or by any means, except duplication of documentation by the purchaser for backup purpose, without written consent of ASRock Inc. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners' benefit, without intent to infringe. Disclaimer: Specifications and information contained in this manual are furnished for informational use only and subject to change without notice, and should not be constructed as a commitment by ASRock. ASRock assumes no responsibility for any errors or omissions that may appear in this manual. [. . . ] 22) 1 GND +5VA BACKOUT-R BACKOUT-L AUD-OUT-L DUMMY AUD-OUT-R MIC-POWER MIC 17 System Panel Header (9-pin PANEL1) (see p. 8 No. 16) 1 PLED+ PLEDPWRBTN# GND This header accommodates several system front panel functions. DUMMY RESET# GND HDLEDHDLED+ Chassis Speaker Header (4-pin SPEAKER 1) (see p. 8 No. 15) 1 SPEAKER DUMMY DUMMY +5V Please connect the chassis speaker to this header. Chassis Fan Connector (3-pin CHA_FAN1) (see p. 8 No. 17) GND +12V CHA_FAN_SPEED Please connect a chassis fan cable to this connector and match the black wire to the ground pin. Please connect the CPU fan cable to this connector and match the black wire to the ground pin. Please connect an ATX power supply to this connector. CPU Fan Connector (3-pin CPU_FAN1) (see p. 8 No. 6) GND +12V CPU_FAN_SPEED ATX Power Connector (20-pin ATXPWR1) (see p. 8 No. 2) Please note that it is necessary to connect a power supply with ATX 12V plug to this connector. Failing to do so will cause power up failure. Game Port Header (15-pin GAME1) (see p. 8 No. 21) 1 +5V JBB1 JBX MIDI_OUT JBY JBB2 MIDI_IN Connect a Game cable to this header if the Game port bracket is installed. +5V JAB2 JAY GND GND JAX JAB1 +5V 18 2. 7 AT (SAT Serial ATA (SATA) Hard Disks Installation This motherboard supports Serial ATA (SATA) hard disks and RAID functions. STEP 1: Install the SATA hard disks into the drive bays of your chassis. STEP 3: Connect one end of the SATA data cable to the motherboard's SATA connector. STEP 4: Connect the other end of the SATA data cable to the SATA hard disk. 2. 8 Realtek Audio Driver Installation For Windows ME If your system is Windows ME, please make sure to install USB 2. 0 driver before installing Realtek Audio driver; for other driver installation, please follow the driver order in our support CD. 19 2. 9 Installing Windows 2000 / Windows XP / Windows XP 64-bit With RAID Functions If you want to install Windows 2000, Windows XP or Windows XP 64-bit on your SATA HDDs with RAID functions, please follow the below steps. Insert the ASRock Support CD into your optical drive to boot your system. During POST at the beginning of system boot-up, press <F11> key, and then a window for boot devices selection appears. When you see the message on the screen, "Do you want to generate Serial ATA driver diskette [YN]?", press <Y>. Then you will see these messages, Please insert a diskette into the floppy drive. Please insert a floppy diskette into the floppy drive, and press <Y>. The system will start to format the floppy diskette and copy SATA drivers into the floppy diskette. Set the "SATA Operation Mode" option from [non-RAID] to [RAID]. STEP 3: Use "RAID BIOS Setting Utility" to set RAID configuration. Before you start to configure the RAID function, you need to check the installation guide in the Support CD for proper configuration. Please refer to the document in the Support CD, "Guide to SATA Hard Disks Installation and RAID Configuration", which is located in the folder at the following path: . . [. . . ] Configuration options: [Disabled], [300], and [330]. 34 3. 3. 8 USB Configuration BIOS SETUP UTILITY Advanced USB Configuration USB Controller USB 2. 0 Support Legacy USB Support [Enabled] [Enabled] [Disabled] To enable or disable the onboard USB controllers. +F1 F9 F10 ESC Select Screen Select Item Change Option General Help Load Defaults Save and Exit Exit v02. 54 (C) Copyright 1985-2003, American Megatrends, Inc. USB Controller Use this item to enable or disable the use of USB controller. USB 2. 0 Support Use this item to enable or disable the USB 2. 0 support. Legacy USB Support Use this item to enable or disable the support to emulate legacy I/O devices such as mouse, keyboard, . . . Or you may select [Auto] so that the system will start to auto-detect; if there is no USB device connected, "Auto" option will disable the legacy USB support. 3. 4 Hardware Health Event Monitoring Screen In this section, it allows you to monitor the status of the hardware on your system, including the parameters of the CPU temperature, motherboard temperature, CPU fan speed, chassis fan speed, and the critical voltage. BIOS SETUP UTILITY Boot H/W Monitor Main Advanced Security Exit Hardware Health Event Monitoring CPU Temperature M / B Temperature CPU Fan Speed Chassis Fan Speed Vcore + 3. 30V + 5. 00V + 12. 00V : 37 C / 98 F : 31 C / 87 F : 2833 RPM : N/A : : : : 1. 532 V 3. 129 V 4. 877 V 11. 741 V F1 F9 F10 ESC Select Screen Select Item General Help Load Defaults Save and Exit Exit v02. 54 (C) Copyright 1985-2003, American Megatrends, Inc. 35 3. 5 Boot Screen In this section, it will display the available devices on your system for you to configure the boot settings and the boot priority. Main Advanced BIOS SETUP UTILITY H/W Monitor Boot Security Exit Boot Settings Boot Settings Configuration 1st Boot Device 2nd Boot Device 3rd Boot Device Removable Drives [1st Floppy Device] [HDD: PM-MAXTOR 6L08] [CD/DVD: SM-CD-ROM] Configure Settings during System Boot. Enter F1 F9 F10 ESC Select Screen Select Item Go to Sub Screen General Help Load Defaults Save and Exit Exit v02. 54 (C) Copyright 1985-2003, American Megatrends, Inc. 3. 5. 1 Boot Settings Configuration BIOS SETUP UTILITY Boot Boot Settings Configuration Boot From Network Bootup Num-Lock [Disabled] [On] To enable or disable the boot from network feature. +F1 F9 F10 ESC Select Screen Select Item Change Option General Help Load Defaults Save and Exit Exit v02. 54 (C) Copyright 1985-2003, American Megatrends, Inc. Boot From Network Use this item to enable or disable the Boot From Network feature. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ASROCK K8UPGRADE-NF3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ASROCK K8UPGRADE-NF3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.