User manual BEGLEC FLEXI LED V1.0

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BEGLEC FLEXI LED. We hope that this BEGLEC FLEXI LED user guide will be useful to you.


BEGLEC FLEXI LED V1.0: Download the complete user guide (1211 Ko)

Manual abstract: user guide BEGLEC FLEXI LEDV1.0

Detailed instructions for use are in the User's Guide.

[. . . ] To be used with our 100% compatible range of LED Managers when dimming is important Big light output (up to 3x more than RGB-version) thanks to the use of 5050 size LEDs Elegant "slim line" design !To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even cause damages. If a foreign object enters the unit, immediately disconnect the installation setup from the mains power. [. . . ] CONNECTION WIRES: used to connect the FlexiledTM to a LED power supply: SINGLE COLOR VERSION: only 2 wires are used. If you don't want to dim the FlexiledTM, you can connect these 2 wires to the LED PSU-50W/24V (order code: 4935). If you want to dim the FlexiledTM, you can connect the wires to one of our LED Managers (different models, see later to learn about how to make the connections) RGB VERSION: uses 4 wires to connect one of our LED Managers (different models, see later to learn about how to make the connections) 6. IP65 SEALING: FlexiledTM comes with sealed wires, if you want to add wires yourself and the FlexiledTM is used in a humid environment than you should add heat shrink (see chapter "electrical installation") Thanks to the special silicon installation jacket, the FlexiledTM can be mounted in different ways. Mounting with double sided adhesive tape: Used to install the FlexiledTM on smooth surfaces where you are not allowed to make holes: mirrors, glass, etc. Thanks to the silicon jacket the glue of the double sided adhesive tape will not warm up and become sticky, as a result you will get good long-term results. Just take good quality double sided adhesive tape (optional, not included) and cut it to size. Put it on the bottom of the silicon installation jacket and fix the jacket to the surface. When the jacket is in place, you can install the FlexiledTM easily inside the jacket. Mounting with small screws or staples: Used to install the FlexiledTM on any surface where you are allowed to make holes: walls, wooden furniture, etc. Thanks to the silicon jacket you can use small screws, nails or even staples to fix the silicon installation jacket. Just take the silicon installation jacket and fix it to the surface with nails, staples, etc. When the jacket is in place, you can install the FlexiledTM easily inside the jacket. Hint: You can install the FlexiledTM also behind translucent plastic panels to create color changing walls and ceilings or in a bar you can install the strips under a translucent shelf to light up bottles and drinking glasses from the bottom. ) so when you install 3 single color FlexiledTMs (5m each) to a LED Manager, they will consume 3 times more than 1 FlexiledTM RGB: 3x 33W = 99W. With longer connection cables you even have to add around 10% (99W becomes 109W!Connecting FlexiledTM single color to a LED PSU 50W/24V: If you don't need to dim the FlexiledTM single color, this is definitely the best and most economical solution. Always check if the power consumption of the FlexiledTM is lower than the maximum power of the LED PSU. When you install more than 1 FlexiledTM, please check the maximum output power of the LED Manager. Don't forget to add 10% to cover the losses while using longer connection cables. The electrical installation should be carried out by qualified personal only, according to the regulations for electrical and mechanical safety in your country. VERY IMPORTANT: Check the user manual of the LED Manager for the maximum allowed power on its outputs! [. . . ] FlexiledTM single color: The contacts named R, G & B should be connected together, a black wire can be soldered. Important: if the installation is used outside or in a humid environment, the connections should be sealed with a combination of shrink sleeve and silicon glue. Since the FlexiledTM is controlled by the LED Manager, we strongly advice to read the operation instructions in the LED Manager user manual. Switch off the LED Manager and unplug the mains cable before you start servicing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC FLEXI LED




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC FLEXI LED will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.