User manual BEHRINGER MDX4400
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual BEHRINGER MDX4400. We hope that this BEHRINGER MDX4400 user guide will be useful to you.
You may also download the following manuals related to this product:
BEHRINGER MDX4400 (1015 ko)
BEHRINGER MDX4400 (928 ko)
BEHRINGER MDX4400 (945 ko)
BEHRINGER MDX4400 (943 ko)
BEHRINGER MDX4400 (1310 ko)
BEHRINGER MDX4400 (933 ko)
BEHRINGER MDX4400 (920 ko)
BEHRINGER MDX4400 (942 ko)
BEHRINGER MDX4400 (914 ko)
BEHRINGER MDX4400 (944 ko)
BEHRINGER MDX4400 (896 ko)
BEHRINGER MDX4400 TECHNICAL SPECIFICATIONS (347 ko)
Manual abstract: user guide BEHRINGER MDX4400
Detailed instructions for use are in the User's Guide.
[. . . ] MULTICOM PRO MDX4400
Users Manual
Version 1. 3 April 2001
®
www. behringer. com
ENGLISH
E
MULTICOM PRO MDX4400
SAFETY INSTRUCTIONS
CAUTION: To reduce the risk of electric shock, do not remove the cover (or back). No user serviceable parts inside; refer servicing to qualified personnel.
WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture. This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosurevoltage that may be sufficient to constitute a risk of shock. This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. [. . . ] The MULTICOM PRO converts two channels to stereo mode by engaging one of the COUPLE switches, where the left of the channels assumes the control of both audio channels, i. e. By pressing the COUPLE switch, you override all the controls and switches of channel 2 (or 4) with the exception of the IN/OUT and SC Filter switches as well as the peak limiters THRESHOLD control. The controls of channel 1 (or 3) take over all functions of channel 2 (or 4).
9
+
10 11
14
4. CONTROLS
MULTICOM PRO MDX4400
4. 4 Rear Panel Control Elements Of The MULTICOM PRO
12 16
13
15
Fig. 4. 5: Control elements of the rear panel
14
12
FUSE HOLDER / VOLTAGE SELECTOR. Please make sure that your local voltage matches the voltage indicated on the unit, before you attempt to connect and operate the MULTICOM PRO. Blown fuses may only be replaced by fuses of the same type and rating. These are the audio inputs of your MULTICOM PRO, available both as balanced 1/4" jack and XLR connectors. With the OPERATING LEVEL switch you can adapt the MULTICOM PRO to various operating levels, i. e. you can select both the -10 dBV home recording level and the professional studio level of +4 dBu. The level meters are referenced automatically to the selected level, i. e. an optimum operating range of the meters will always be ensured.
13 14 15 16
4. APPLICATIONS
In this section, several typical applications of the BEHRINGER MULTICOM PRO are discussed. Please take the time to study the application examples carefully, in order to be able to make full use of the MULTICOM PROs capabilities in the future. Main Applications And Initial Settings The main applications of the BEHRINGER MULTICOM PRO can be divided into two categories: The compressor section is used to compress the program material and to create special effects and unusual sounds, which are used for recording and musical performance. The subsequent Peak Limiter section is designed to protect loudspeakers, tape recorders, transmitters etc. from being overloaded.
5. 1 Compression/Leveling/Limiting/Clipping
Now that the functions of the individual sections have been clearly explained, we would like to acquaint you with more terms and relationships of the dynamics process. Compression A compressor converts a large dynamic level into a restricted range. The extent of the resulting dynamic level is dependent on the threshold, attack, release and ratio settings. As it is the desired effect of a compressor to increase a low level signal, generally the threshold is set low. The inaudible compression mode requires fast attack and release times and low ratios. The faster the chosen control times and the higher the compression ratio, the greater the effect on the short term dynamics. [. . . ] To obtain warranty service, the buyer (or his authorized dealer) must call BEHRINGER (see enclosed list) during normal business hours BEFORE returning the product. Subsequently, the product must be returned in its original shipping carton, together with the return authorization number to the address indicated by BEHRINGER. Warranty services will be furnished only if the product is accompanied by a copy of the original retail dealers invoice. Any product deemed eligible for repair or replacement by BEHRINGER under the terms of this warranty will be repaired or replaced within 30 days of receipt of the product at BEHRINGER. [. . . ]