If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITADEL XR1-ENGINEERING INFORMATION. We hope that this CITADEL XR1-ENGINEERING INFORMATION user guide will be useful to you.


CITADEL XR1-ENGINEERING INFORMATION : Download the complete user guide (1055 Ko)

Manual abstract: user guide CITADEL XR1-ENGINEERING INFORMATION

Detailed instructions for use are in the User's Guide.

[. . . ] Calculate the total current consumption of every part of the system including the panel, remote keypads, bell/sounders, strobes and detectors to ensure that this rating is not exceeded. I 2 4188-693 issue 1_8/01 Citadel XR1G3 Intruder system Depending on which area you live, you may be required, by law to notify the Local Authority and Police of the new security alarm installation. The local authority requirements may differ from area to area, therefore, it is advisable to contact local environmental officer to obtain full details of your area requirements. Engineering information Note: When replacing the PCB align it on the round support pillars to the bottom and allow it to click down past the clips at the top of the case. There are cable entry holes provided in the rear of the base and around the outside edges through the thinned out plastic sections which may be cut away as required. The hole provided adjacent to the mains transformer is a dedicated mains cable entry point. Mounting holes LA Fixing Caution: When positioning the control panel ensure that it is located in a dry place away from damp areas. a. [. . . ] Before entering engineer program mode the system should be in the Day mode, with the Day and Power indicators lit. Key LED steady On indication LED flashing indication LED Off Internal sound Sound description 9 9 9 9 Acknowledge Tamper Day To Exit Engineer program mode Reset Day To reset panel to Factory set conditions Caution: All configurations of the panel are restored to factory `default' conditions. Within 5 seconds of powering up the panel Reset Reset NOTE: In general a flat beep is an indication of an incorrect key press. External devices Strobe Bell reset beeps To exit Reset Quit the current function Leave program menu Down one menu level 4188-693 issue 1_8/01 11 Testing the system Engineering information Citadel XR1G3 Intruder system Example: To change User 1 code to 3457 Press: Prog Access Codes There are three codes used in the system, all are 4 digit and can be set to any number from 0000 to 9999. The access codes ensure that only authorised users can operate the system. User 1 and 2 codes The user 1 and user 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code. Engineer code Accesses the Engineer Program mode to allow the system to be programmed. If configured the Engineers access code can be used to reset the system after an alarm. 9 4 9 5 9 7 9 Reset 8 Reset 1 3 Enter Engineer program mode 8 Codes Attack 1 2 9 Change User code 1 Change User code 2 Change Engineer code Day ZONE 1-4 Access Codes Note: Entering an invalid user code will operate the code tamper. After nineteen incorrect key pushes a full alarm condition will be generated. n n n n New code NOTE - The sounder will produce a flat beep if the code is rejected. The Code is rejected if it is already in use. Rising beeps ZONE 1-4 Day Reset Exit codes Attack Reset Leave engineer mode Day Acknowledge Tamper 12 4188-693 issue 1_8/01 Citadel XR1G3 Intruder system Engineering information Programs The panel uses 3 Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function. The examples below show how 3 typical Programs could be used in a house. Exit Modes program Timed A timed Program will become Set as the Exit timer expires. Terminated Set This sets an infinite time out, which will only set once the PTS input is operated. Final Door A final door program will be Set 5 seconds after a timed zone has opened and closed. Silent Set This operates exactly the same as `Timed' but completely silent without the internal sounder signal. ÿ ÿ ÿ Program 1 : To arm all of the zones and become Set as the user leaves the property and closes the final door. Program 2 : To protect the perimeter of the property in the evening and become Set after say 20 seconds. Program 3 : To protect the downstairs areas of the house at night and become Set instantly and silently. Zone Function per Program Timed : This function would be used to protect the main entry/exit door of the entry route. Time inhibited : This is a zone which, on setting the panel, allows access to the Entry / Exit zone. However, if the panel is set and an time inhibited zone is triggered before an Entry /Exit zone then an alarm will be generated immediately. Immediate: This is a zone which will, when entered, go into alarm when the panel is set. Unused : A zone that is programmed as an Unused zone by the Engineer, then is ignored by the panel. Primarily used for Part set options. 4188-693 issue 1_8/01 13 Programs Note: The above are purely examples. The installer must program the panel to configure all the circuits to the customer's exact requirements. Note: If a program is not selected when the user Sets the system, Program 1 will automatically Set. [. . . ] Normally closed detectors must be wired together in a series loop before connecting into the appropriate ZONE terminals. Where a permanent zone fault is showing and the loop resistance is found to be in order, the most probable cause is a short circuit between the zone wiring and the tamper wiring. When measured with a multimeter the series resistance between the zone and tamper wiring should be infinitely high. If totally lost as to the cause of a fault, remove ALL wiring from the PCB. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE CITADEL XR1-ENGINEERING INFORMATION




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual CITADEL XR1-ENGINEERING INFORMATION will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.