If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual CITADEL XR2-ENGINEERING INFORMATION. We hope that this CITADEL XR2-ENGINEERING INFORMATION user guide will be useful to you.
Manual abstract: user guide CITADEL XR2-ENGINEERING INFORMATION
Detailed instructions for use are in the User's Guide.
[. . . ] XR2/ XR2+
Features
Power
Intruder alarm system Engineering Information
RKP PART SET
8z
MEM
4
REMOTE
8
6
OUTPUT
5 09
SET
ÿ
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 Tamper Attack
8 zones, all programmable for Security, Fire, 24H Fire, PTS or keyswitch applications PA input Tamper input Outputs for Bell and Strobe 4 Access level Codes, User 1, User 2 and Engineer and Duress, all programmable 3 fully selectable part set programs Chime on any zone 8 event memory Programmable timers including bell cut off Walk Test facilities Quick set feature Remote keypad with on board PA and illuminated keys Option for connection of Lighting controllers Options to connect up to four remote keypads / Lighting controllers NVM for protection of engineer programme 6 digital outputs for a wire-in digital communicator, Red Care STU or dialler Service warning indicator, programmable between 100 and 800 set and unset events Battery capacity of up to : 2. 1Ah in XR2 enclosure 7Ah in XR2+ enclosure Features
0 5
Chime
1 6
Omit
2 7
Reset
3 8
Prog
4
PA
9
Set
Day
Power
8SP 403 XR2+ G3 panel with remote LED keypad
ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ ÿ
Power
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 Tamper Attack
0 5
Chime
1 6
Omit
2 7
Reset
3 8
Prog
4
PA
9
Set
Day
Power
Accenta/!mini
8SP 404 XR2 G3 panel with remote LED keypad
The above intruder system is designed to comply with the installation requirements of BS 4737 1986/87. This manual provides information on Installation design, panel fixing, wiring, power up and programming of the intruder panel.
4188-694 issue 1_8/01
1
Downloaded from: http://www. guardianalarms. net
Engineering information
Contents
Features - - - - - - - - - - - - - Installation Design - - - - - - - - Fixing - - - - - - - - - - - - - - Wiring the system - - - - - - - - Tamper network - - - - - - - - - Connecting Remote Keypads / Lighting controllers - - - - - - - Fixing the Remote Keypad (RKP) Security zones - - - - - - - - - - Push to set zone - - - - - - - - - Remote keyswitch zone - - - - - Fire zone - - - - - - - - - - - - PA circuit - - - - - - - - - - - - Extension speaker - - - - - - - - Bell Output (External sounder) - - 13V Supply output - - - - - - - - Set - - - - - - - - - - - - - - - Remote signalling Input and Outputs 1 2 3 4 4 5 5 5 6 6 7 7 8 8 9 9 9 11 12 12 13 13 13 13 13 13 14 15 15 15 16 17 18 18 19 19 20 21 22 23 24 25 26 27 31 31 32
Citadel XR2/XR2+ G3 Intruder system
Installation Design
The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding and then follow the procedures and advice contained in this manual. [. . . ] Restore of the Intruder Output The intruder alarm output is restored to 12V whenever a user code is entered or a keyswitch is used to switch off an intruder alarm condition. Where an intruder alarm is shortly followed by a restore at the ARC, this can be used to filter the alarm.
c.
10
4188-694 issue 1_8/01
Citadel XR2/XR2+ G3 Intruder system
Engineering information
Factory set condition
User code 1 - User code 2 - Duress Code - Engineer Code Bell Duration Bell Delay - - Program 1 Zone 1 - - Zone 2 - - Zones 3. . . 8 Exit time- Entry - - Exit mode Program 2 Zone1 - - Zone 2 - - Zone 3. . . 8 Exit time- Entry time Exit mode Program 3 Zone 1 - Zone 2 - Zone3. . . 8 Exit timeEntry time Exit mode 0123 Not programmed Not programmed 9999 20 minutes No delay Flag A Silent PA - - - - - - RKP PA Enable - - - Engineer Reset- - - - Anti Code Reset - - - Door bell on push to set Single key setting - - Strobe on setting - - - External bell on Fire - Flag B Communicator Output active high - - - - - Line Fail active high - - - - - User Reset PA - - - User Reset Fire - - - Program 1 to report - Program 2 to report - Program 3 to report - Rearm counter - - - Service counter - - - Site Code - - - - - - Light Controller Light Threshold Light Hold Time Light Channel 1 Light Channel 2 Light Channel 3 Light Channel 4 Light Channel 5 Light Channel 6 Light Channel 7 Light Channel 8 -
-
-
-
-
-
-
Timed Time Inhibited Immediate 30seconds 30seconds timed
-
-
No Yes No No No No No No
- - - - No (active low) No (active low) No No Yes Yes Yes 3 (re-arms) Off 00 Factory set condition
-
-
-
-
-
-
Timed Time inhibited Immediate 30seconds 30seconds Disabled
-
-
-
-
-
-
-
Timed Time Inhibited Immediate 30seconds 30seconds Disabled Zones 1. . . 8 None programmed None programmed None programmed None programmed None programmed None programmed 300mS ALL zones
Security Zones - - - Standard Fire zones 24 hour Fire zones - Push to set zones - - Keyswitch zones - - Double Knock zones Omit prevent zones- Zone debounce period
-
-
-
-
-
50% 30 seconds No zones assigned No zones assigned No zones assigned No zones assigned No zones assigned No zones assigned No zones assigned No zones assigned
4188-694 issue 1_8/01
11
Engineering information
Citadel XR2/XR2+ G3 Intruder system Note: The panel is not supplied with wire links for unused zones. All unused zones must be programmed out by setting them to disabled using the Zone Type function see page 20.
First Power up
To power up for the first time: a. Check that the factory fitted links are connected to terminals PA, TAMP and T-A. Fit the battery wires to the BATT terminals on the PCB, Red to + and Black to -.
Panel
BATTERY
b.
Mains Connection
The mains power should be connected using a 3 core cable of not less than 0. 75mm sq. The 2A fused spur must be located close to the control panel.
Dedicated mains supply from consumer unit.
F1
Board
J4 +BATT AC
1. 6A
(red) +
Black -
N E L 125mA Fuse
2A Fused Spur unit
Panel
BATTERY
F1
Board
J4 +BATT AC
First Power up
12V battery
Transformer
c.
On connecting the battery the system will now go into alarm condition and Tamper is indicated
Tamper
1. 6A
and there is an audible
(red) +
Black -
N E L 125mA Fuse Transformer
d.
Alarm. Fit the cover to hold down the tamper spring at the bottom centre of the PCB.
12V battery
e.
Enter the user code: 0 1 2 3 (factory set at 0123). Immediately enter the engineer code
Prog
Day
Note: The mains supply must be connected by a technically competent person and according to current IEE regulations. Caution: To avoid the risk of electrical shock you must always totally isolate the mains supply before opening the control panel cover(s).
Mains Input Fuse rating: 125mA, 250V type T (anti surge) and of a type approved to IEC 127 part 2 sheet III. On connecting the mains supply to the panel the power indicator is lit.
Power
f.
. Note the
Tamper
9
9
9
9
ÿ
Tamper indicator is lit.
12
4188-694 issue 1_8/01
Citadel XR2/XR2+ G3 Intruder system
Engineering information
Testing the system
Complete the wiring of the system and then:
System indications
Day Power
ÿ ÿ ÿ ÿ
- Unset system indication
Fully test the system and ensure it is fault free. Fill in the installation log at the back of the manual and retain if for future reference. Detach them and leave them with the user.
Power
- Set system indication
To enter Engineer program mode
Note: The factory configured engineer's access code is 9999. If however this code is changed then enter the appropriate code.
Prog
ZONE 1 - 8 Momentarily On
Engineer program mode
The panel may be programmed to suit a wide variety of installations. Once the engineer program mode has been accessed, each configuration may be changed in any order. As each configuration is completed the system will automatically return to top level of engineer program mode. Before entering engineer program mode the system should be in the Day mode, with the Day and Power indicators lit. Keys
9
9
9
9
Acknowledge
Tamper
Day
To Exit Engineer program mode
Reset
Day
LED steady On indication LED flashing indication LED Off
o/p ARC Output to Alarm Receiving Centre
To reset panel to Factory set conditions
Caution: All configurations of the panel are restored to factory `default' conditions.
Within 5 seconds of powering up the panel
Reset Reset
Internal sound
Sound description
NOTE: In general a flat beep is an indication of an incorrect key press. External devices Strobe Bell
reset beeps
To exit
Reset
Quit the current function Leave program menu Down one menu level
4188-694 issue 1_8/01
13
Testing the system
Engineering information
Citadel XR2/XR2+ G3 Intruder system
Example: To change User 1 code to 3457 Press:
Prog
Access Codes
There are four codes used in the system, all are 4 digit and can be set to any number from 0000 to 9999. The access codes ensure that only authorised users can operate the system. User 1 and 2 codes The user 1 and user 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code. Duress code Should be used in a hold up situation where there is pressure to Set or Unset the system. [. . . ] This anti-code is generated from a small computer program which is installed at most UK Alarm receiving Centres, or alternatively can be run on a PC by the engineer. Security of the anti-code reset system is maintained by a 2 digit site code which is set up in the anti-code generator programme. The same 2 digit site code must also be set up in the control panel during installation.
Zone 1
0 0 0 9
0 1 3 9
No re-arm 1 re-arms 3 re-arms (factory default) 99 re-arms
Zone 2 Day
Zone 1
0
Zone 2
0 1 0 9
0
Day
factory default code 01 20 99
2 9
Acknowledge
Day
Reset
Exit to Timer and counters Leave program mode
Day Acknowledge Tamper
Attack
Reset
4188-694 issue 1_8/01
23
Engineering information
Citadel XR2/XR2+ G3 Intruder system
Lighting controller
Example: To assign zones 1 and 2 to lighting controller channel 1, Press: Prog 9 9 9 9 9 1 1 2 Reset Reset Reset Enter Engineer program mode Lighting 9 Controller
Attack
All Zones
To assign zones to channel press to select and again to deselect zone (Factory default: No zones are selected)
1 2 3 4 5 6 7
Channel 1 1 assigned zones Channel 2 2 assigned zones
Press a number button to select the appropriate light channel
Lighting controller
Channel 3 3 assigned zones Channel 4 4 assigned zones
5
Appropriate Zone indicator is lit to identify its assignment to channel
Day Zone n assigned to the channel Zone n not assigned to the channel
Channel 5 assigned zones
Channel 6 6 assigned zones Channel 7 7 assigned zones Channel 8 8 assigned zones
8
Reset
Exit current level Exit Lighting controller
Attack
Hold time (0-99 seconds) 9 (20 seconds factory default)
Prog
Reset
Set the light threshold level (0 - 99%)
Reset
Leave program mode
Day Acknowledge Tamper
Day
0
Zone 1
0
0% threshold or 0 second hold time 1% threshold or 1 second hold time 20% threshold or 20 seconds hold time
acknowledge
Day
Zone 2
0
1
Reset
Exit Lighting controller
2
0
Attack
Reset
Leave program mode
Day Tamper Acknowledge
24
4188-694 issue 1_8/01
Citadel XR2/XR2+ G3 Intruder system
Engineering information
g. Fuses which fail continually are almost certainly the result of a short circuit or low resistance across the 13V supply or external bell supply (terminal D). [. . . ]