User manual DSC PC550

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSC PC550. We hope that this DSC PC550 user guide will be useful to you.


DSC PC550 : Download the complete user guide (308 Ko)

Manual abstract: user guide DSC PC550

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual PC55O With PC5OORK Keypad Industry Canada Notice NOTICE: The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. Industry Canada does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. [. . . ] The keypad will sound a series of short beeps once the system has accepted the alarm. Press and hold the [A] Key for 2 seconds to generate an [A] Key alarm. Your installer will inform you of how this alarm will operate; this alarm may be programmed to activate a device, such as a door lock or a warning light. The keypad will sound a series of short beeps once the system has accepted the alarm. The alarm may be programmed as either silent or audible; your installer will inform you of how this alarm will operate. If your installer has programmed this alarm to be audible, the keypad will sound a series of short beeps once the system has accepted the alarm, and the siren will sound a steady tone. [A] [P] Utility Output Command A special keypad command may be used to operate various devices connected to your security system. When the command is entered, the keypad will sound a single tone for 5 seconds, and the Utility Output will be activated for 5 seconds. This command may be used to operate devices such as special lighting or door strikes. Your installer will inform you of how the Utility Output function is set up on your system. 5 ARMING OPTIONS At-Home Arming At-Home Arming automatically bypasses the zones on your system programmed as Home-Away with Delay, and also removes the Entry Delay from the Entry-Exit Zones. In addition, if any of the Entry-Exit doors are opened, an alarm will sound instantly. To use At-Home Arming, enter [ ][9][Access Code] on the keypad. The "Armed" light will FLASH to remind you that there is no Entry Delay on the Entry-Exit doors. Home-Away Arming Home-Away arming automatically bypasses the zones on your system programmed as Home Away with Delay, and applies the Entry Delay to the Entry-Exit zones. For example, you could use this feature to arm the system and remain on the premises. Another household member would still be able to enter the premises through the Entry-Exit door without causing an alarm. When the Entry-Exit door is opened, an Access Code would have to be entered to disarm the system. To arm the system with Home-Away Arming, enter an Access Code and do not open the Entry-Exit door. When the Exit Delay expires, the system will be armed with the Home-Away with Delay zones automatically bypassed. Your Installer will inform you of which zones on your system have been defined as "Home-Away with Delay" zones. Quick-Arm The Quick-Arm feature allows you to enter [ ][0] to arm the system. This command is designed to allow someone to arm the system without that person having to be provided with an Access Code. When [ ][0] is entered, the Exit Delay will begin and the user may leave the premises through the Entry-Exit door. At the end of the Exit Delay, the "Armed" light will come ON and the system will be fully armed. 6 PC500RK KEYPAD The "Ready" light will come ON when the system is ready to be armed. When the "Ready" light is OFF, there is an open zone on the system. The "Armed" light will come ON to indicate that the system is armed. The "Armed" light will FLASH to indicate that the system is armed and that there is no Entry Delay on any of the zones. The "System" light will come ON to indicate: · that zones are bypassed · there is a trouble condition on the system · there are alarms in memory. [. . . ] These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Re-orient the receiving antenna. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSC PC550




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSC PC550 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.