User manual DSE 5220

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual DSE 5220. We hope that this DSE 5220 user guide will be useful to you.


DSE 5220 : Download the complete user guide (1085 Ko)

Manual abstract: user guide DSE 5220

Detailed instructions for use are in the User's Guide.

[. . . ] COMPLEX SOLUTIONS MADE SIMPLE. DEEP SEA ELECTRONICS PLC DSE5220 AUTO MAINS FAILURE MODULE OPERATING MANUAL DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723 890099 Sales Fax: +44 (0) 1723 893303 E-mail: sales@Deepseaplc. com Website: www. deepseaplc. com DSE Model 5220 Control and Instrumentation System Operators Manual © Deep Sea Electronics Plc All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder except in accordance with the provisions of the Copyright, Designs and Patents Act 1988. Applications for the copyright holder's written permission to reproduce any part of this publication should be addressed to Deep Sea Electronics Plc at the address above. Any reference to trademarked product names used within this publication is owned by their respective companies. [. . . ] The alarm must be accepted and cleared, and the fault removed to reset the module. In the event of an electrical trip alarm the icon will illuminate. is displayed followed by the flashing shutdown Additionally, During the cooling timer the warning symbol symbol when the cooling timer has expired. AUXILIARY INPUTS, if an auxiliary input has been configured as an electrical trip the appropriate LCD segment will be displayed:- ! GENERATOR HIGH CURRENT. If the module detects a generator output current in excess of the pre-set trip a warning is initiated. If this high current condition continues for an excess period of time, then the alarm is escalated to either a shutdown or electrical trip condition (depending upon module configuration). For further details of the high current alarm, please see High Current Shutdown Alarm. A 5220 OPERATING MANUAL ISSUE 5. 1 18-Jun-07 AM 15 DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual 5 LCD INDICATORS AND LOGO INSERT USER CONFIGURABLE LCD indicators These indicators can be configured by the user to indicate any one of 100+ different functions based around the following:· INDICATIONS - Monitoring of a digital input and indicating associated functioning user's equipment - Such as Battery Charger On or Louvre Open, etc. · WARNINGS and SHUTDOWNS - Specific indication of a particular warning or shutdown condition, backed up by LCD indication - Such as Low Oil Pressure Shutdown, Low Coolant level, etc. · STATUS INDICATIONS - Indication of specific functions or sequences derived from the modules operating state - Such as Safety On, Pre-heating, Panel Locked, Generator Available, etc. Additionally the module's logo can be changed to suit generator manufacturer's requirements. This can be used for instance to give custom branding to the module, or even include the service telephone number. DSE have produced the `insert card creator' software, shipped with the DSE Software CD to ease the production of text and logo insert cards to suit your application. Removal and insertion of the text insert card Removal and insertion of the Logo insert card 16 057-012 5220 OPERATING MANUAL ISSUE 5. 1 18/06/2007 AM DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual 6 DESCRIPTION OF CONTROLS The following section details the function and meaning of the various controls on the module. Scroll Configure / log Stop Manual Test Auto Start FIG2 5220 OPERATING MANUAL ISSUE 5. 1 18-Jun-07 AM 17 DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual 6. 1 TYPICAL LCD DISPLAY SCREENS The LCD displays the various engine parameters such as `ENGINE SPEED', `OIL PRESSURE', `HOURS RUN', etc. In this example, the values being displayed are Generator phase to neutral L1-N, AC voltages V. INSTRUMENTS STATUS ICONS The LCD also displays the status of the controller by showing (for example) an hourglass symbol when a timer is in progress or by displaying a common alarm symbol. This display is indicating that a timer is in progress and a warning alarm is present. See the `Protections' section of this manual for details of the alarms. In this example the values being displayed are the three generator USER DEFINED INDICATIONS AC currents A The LCD displays the user-defined indications when configured and active. The icons will illuminate and point to the appropriate text insert label. These indications can be used to indicate the operation of external equipment (i. e. `Battery Charger On', `Breaker Closed' etc) or to indicate internal states (i. e. Engine Running, Safety On, etc). USER DEFINED ALARMS The LCD displays the user-defined alarms when configured and active. The icons will illuminate and point to the appropriate text insert label. These alarms can be used to indicate the operation of external alarms (i. e. `Low Fuel Level', `Low Coolant level' etc) or to indicate internal alarms (i. e. HOURS RUN COUNTER The LCD displays the generator hours run time while both the generator symbol and the clock symbol are present. [. . . ] This can be supplied by a Mains/Utility monitoring module to make the generating set start up automatically should the mains/utility supply fail. The 5210 module may be used in conjunction with DSE Automatic transfer switch controllers such as the model 500 (pictured) , 705 or 530. These not only monitor the mains and issue a start command to the 5210; they also provide control of the contactors or other changeover devices. Please refer to our Technical Support department for details. 50 057-012 5220 OPERATING MANUAL ISSUE 5. 1 18/06/2007 AM DSE Model 5220 Automatic Mains Failure & Instrumentation System Operators Manual 15. 9 ENCLOSURE CLASSIFICATIONS IP CLASSIFICATIONS BS EN 60529 Degrees of protection provided by enclosures First Digit Protection against contact and ingress of solid objects 0 1 No protection Protected against ingress solid objects with a diameter of more than 50 mm. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE DSE 5220




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual DSE 5220 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.