User manual FIRENZI FGH610BK

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FIRENZI FGH610BK. We hope that this FIRENZI FGH610BK user guide will be useful to you.


FIRENZI FGH610BK : Download the complete user guide (220 Ko)

Manual abstract: user guide FIRENZI FGH610BK

Detailed instructions for use are in the User's Guide.

[. . . ] When using the hob for a long period of time, the ventilation should be improved, by opening a window or increasing the extractor speed. Ensure the control knobs are in the `OFF' position when not in use. When using other electrical appliances, ensure the cable does not come into contact with the hot surfaces of the cooking appliance. Unstable or misshapen pans should not be used on the hob as unstable pans can cause an accident by tipping or spillage. [. . . ] * This guarantee is in addition to your statutory and other legal rights. Visits may be available outside these hours, in which case a premium will be charged. European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: * The guarantee starts from the date you first purchased your product. * The guarantee is for the same period and to the same extent for labour and parts as exist in the new contry of use for this brand or range of products. * This guarantee relates to you and cannot be transferred to another user. * Your new home is within the European Community (EC) or European Free Trade Area. * The product is installed and used in accordance with our instructions and is only used domestically, i. e. * The product is installed taking into account regulations in your new country. Before you move, please contact your nearest Customer Care centre, listed below, to give them details of your new home. They will then ensure that the local Service Organisation is aware of your move and able to look after you and your appliance. France Senlis +33 (0) 344 62 20 13 Germany Nürnberg +49 (0) 800 234 7378 Italy Pordenone +39 (0) 800 11 7511 Sweden Stockholm +46 (0) 20 78 77 50 UK Slough + 44 (0) 1753 219898 Exclusions This guarantee does not cover: * Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or removable parts of glass or plastic. * Costs incurred for calls to put right an appliance which is improperly installed or calls to appliance outside the United Kingdom. * Appliances found to be in use within a commercial environment, plus those which are the subject to rental agreements. 7 Instructions for the Installer Engineers technical data OVERALL DIMENSIONS Width: Depth: Height: 580 mm. SUPPLY CONNECTIONS Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner Electric: 230-240V 50Hz supply, 3 core flexible cable. CUT OUT DIMENSIONS Width: 550 mm. Thickness: 30 mm. Ignition HT Spark Spark Generator Ispra Control's BF 50066 - 230-240V 0. 6 YA T 120 Spark Gap Fixed Rear Left Burner (semi-rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Left Burner (rapid) Heat Input 3. 0 kW (10236 BTU/HR) Rear Right Burner (semi-rapid) Heat Input 2. 0 kW (6824 BTU/HR) Front Right Burner (auxiliary) Heat Input 1. 0 kW (3412 BTU/HR) TYPE OF GAS BURNER Characteristics POSITION VALUE = 37. 78 MJ/m3 Ws - 50. 7 MJ/ m3 RAPID (large) MAX MIN SEMI-RAPID (medium) MAX MIN AUXILIARY (small) MAX MIN NATURAL GAS 20 mbar NOMINAL THERMAL POWER kW NOMINAL FLOW RATE m3/h NOZZLE REFERENCE 1/100 mm NOMINAL THERMAL POWER kW NOMINAL FLOW RATE 3. 0 0. 286 119 0. 65 0. 062 Adjust. 2. 0 0. 190 96 0. 45 0. 043 Adjust. 1. 0 0. 095 70 0. 33 0. 031 Adjust. VALUE = 49. 92 MJ/Kg LPG GAS 28-30/37 mbar 2. 8 0. 65 2. 0 0. 45 1. 0 0. 33 g/h 202 86 47 40 144 71 32 32 72 50 24 28 NOZZLE REFERENCE 1/100 mm Burner Auxiliary Semi-rapid Rapid Dia. Tap By-pass 1/100 mm 28 32 40 APPLIANCE CLASS: 3 APPLIANCE CATEGORY: II2H3+ APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar Aeration adjustment none 8 Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). WHEN THE HOB IS FIRST INSTALLED Once the hob has been installed, it is important to remove any protective materials, which were put on in the factory. On the end of the shaft, which includes the G 1/2" threaded elbow, adjustment is fixed so that the washer is fitted between the components as shown in the diagram. Screw the parts together without using excessive force. 9 Gas Connection Connection to the gas supply should be with either rigid or semi-rigid pipe, i. e. The connection should be suitable for connecting to R 1/ 2" (1/2 BSP male thread). When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Ensure that the main connection pipe does not exert any strain on the hob. It is important to install the elbow correctly, with the shoulder on the end of the thread, fitted to the hob connecting pipe. [. . . ] To adjust, use a thin bladed screwdriver and turn the adjustment screw (see diagram) until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Pressure Testing Remove left hand pan support and front left burner cap and crown. The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar. Turn off the burner supplies. Minimum adjustment screw 14 Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FIRENZI FGH610BK




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FIRENZI FGH610BK will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.