User manual FLUSHMATE 503

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FLUSHMATE 503. We hope that this FLUSHMATE 503 user guide will be useful to you.


FLUSHMATE 503 : Download the complete user guide (104 Ko)

You may also download the following manuals related to this product:

   FLUSHMATE 503 (107 ko)

Manual abstract: user guide FLUSHMATE 503

Detailed instructions for use are in the User's Guide.

[. . . ] NEVER use corrosive chemicals or household cleaners on FLUSHMATE products. INSTALLATION _______________________________________________________________________________ The Sloan FLUSHMATE ® Flushometer -Tank System Fixture installs in the same manner as other water closets. Using the gasket, washer and nuts provided with the fixture, assemble the tank to the bowl. Before connecting the supply to the tank, be sure the supply line is flushed clean. Do this by running water from the supply stop into a bucket until water flows clear. [. . . ] If the Tank continues to run-on, push down lightly on the Flush Valve Actuator. If the water stops running, it is an indication that the Flush Valve Cartridge requires tightening (clockwise). If water still runs on while pushing down on the actuator, the Flush Valve Cartridge requires loosening (counter-clockwise). NOTE: Adjust the Flush Valve Cartridge Assembly in quarter to half turn increments until the water stops running. If replacement of the Flush Valve Cartridge is necessary, follow the instructions in Step 5. If OK, then check the Flush System by removing the tank Cover and tripping the Actuator. Water should flow freely and wash away any debris in the supply line and Vessel. To test the Air Inducer, place a small amount of water (2 to 3 drops) in the orifice of the Air Inducer cap and flush the toilet. If the Air Inducer is functioning properly the water will be drawn in. TO CLEAN AIR INDUCER: (Figures 3 & 4) a) Turn off the water supply and trip the Actuator. b) Unscrew the Air Inducer Cap, clean thoroughly and remove any obstructions. Wait for the Vessel to refill (30 to 60 seconds. ) Repeat Step 2 above. If the Air Inducer does not function properly, replace the Upper Supply Assembly. Turn the water supply off and drain the vessel by tripping the Actuator and holding it down until completely drained. Next, pour a cup of water onto the Cartridge Housing area as shown in Figure 5. If a leak is detected (a steady flow of bubbles from the center of the Cartridge Area), the Cartridge should be replaced. Turn the water off and relieve the Vessel pressure by flushing the toilet. Reattach the supply line to the supply shank and observe connections to assure no leakage. IMPORTANT: If you are still experiencing a weak or sluggish flush after this point, it is recommended you replace the entire Lower Supply group. proper drain ventilation Consult a professional for recommendations if any of these conditions exist. If the drain and drain vent are clear, and the flush has not been improved, replace the Lower Supply Assembly. Air Inducer Cap FIGURE 3 FIGURE 4 FIGURE 5 TROUBLESHOOTING___________________________________________________________________________ CONDITION: No Flush Step 1. Review all of Step 3 and Step 4 covered in "Weak or Sluggish Flush" Condition. [. . . ] Push down on the Actuator one more time, then pull it up momentarily to allow air into the Vessel. Bowl Procedure: After flushing out the Vessel, remove the remaining water from the bowl or add from 1 pint to 1 quart of antifreeze or RV antifreeze to the water remaining in the bowl. NOTE: Refer to fixture manufacturer's instructions for procedures to winterize bowl. POINTS TO REMEMBER________________________________________________________________________ Safety Notice · When servicing any component, the water supply should be turned OFF and the Actuator tripped to relieve the pressure in the Vessel. · The Flush Valve Cartridge Assembly can be removed by inserting the handles of a pair of pliers into the top of the Cartridge and turning counter-clockwise. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FLUSHMATE 503




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FLUSHMATE 503 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.