User manual LA CROSSE TECHNOLOGY WS-7095UM

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS-7095UM. We hope that this LA CROSSE TECHNOLOGY WS-7095UM user guide will be useful to you.


LA CROSSE TECHNOLOGY WS-7095UM : Download the complete user guide (514 Ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS-7095UM

Detailed instructions for use are in the User's Guide.

[. . . ] WS-7095U Wireless 433 MHz 24" Wall Hanging Wireless Weather Center Instruction Manual TABLE OF CONTENTS Topic Inventory of Contents/Additional Equipment: Quick Set-Up Guide: Detailed Set-Up Guide Battery Installation: LCD Screens: Program Mode Function Buttons: LCD Contrast: 12/24-hour Time Display: Time Setting: Time Zone Setting: Date Setting: Date Display: Selecting °F or °C and Inches or Millimeters: Setting Forecast Sensitivity: Displaying Relative/Absolute hPa/inHg: Manually Setting Relative Air Pressure: Setting Bar Graph Display: Features & Operations Moon Phase: Minimum & Maximum Records (Indoor, Outdoor, Resetting): Weather Forecast and Weather Icons: Bar Graph Histories (Air Pressure and Rainfall): Rainfall (Quantity & Resetting): Manual setting of Rain Multiplicator: Hard Reset of EEPROM Weather Center Memory: Adding Sensors: Mounting: Maintenance and Care: Troubleshooting: Specifications: Warranty Information: Page 3 3 4 5 6 6 6 6-7 7 7 7 7-8 8 8-9 9 9 10-11 11-12 12-14 14-16 16-17 17 17-18 18-19 19-22 23 23 24-25 26 2 INVENTORY OF CONTENTS 1. TX4U--Remote Thermo-Hygro Figure 1. 2. Figure 2 (temperature-humidity) Sensor: includes a mounting bracket/receptor, rain cover, two mounting screws, and adhesive tape (Figure 2). TX5U--Rainfall Sensor: includes a Figure 3 base, rainfall collector, and two mounting screws (Figure 3). Wait 12 minutes, or until the Weather Center has received signals from the Remote Thermo-Hygro, and Rainfall Sensors. [. . . ] Each brick on the bar graph represents a value of 0. 03 hPa, and each brick also has a corresponding value on the verticle axis. Multiply the two values to find past air pressure (note the + or ­ sign of values on the verticle axis); i. e. 0. 03 hPa x 3 = 0. 09 hPa, now add this value to the air pressure (in LCD 4) to evaluate what past air pressures have been. Position "0" on both the vertical and horizontal indicate present air pressure. The top bar corresponds with "-1" on the vertical axis, multiply 0. 03 x ­1, we get ­0. 03 hPa. Add ­0. 03 to current air pressure readings to attain the air pressure 1-hour ago. A decline in air pressure is shown between the "-3" and "-1" hours. Air pressure trends can be determined by simply glancing at the bar graph. If the bars are rising (higher on the right than the left) then the 15 air pressure has a rising trend, and the weather should improve. If the bars are dropping (lower on the right than the left) then the air pressure has a falling trend, and the weather should worsen. RAINFALL HISTORY The bar graph will also display the rainfall history; this mode is indicated by the appearance of the word "RAIN" at the top of the LCD 5 screen. The horizontal axis measures the past time periods, with "0" representing the current day, week, or month and "7" representing the oldest information (7 days ago, 7 weeks ago, or 7 months ago). The vertical axis measures the rainfall in either preferred increments of inches or millimeters. The normal (default) measurement scale is: in inches {0, 0. 1, 0. 3, 0. 5, 1, 2, 3, 5, 10}; in millimeters {0, 1, 3, 5, 10, 30, 50, 100}. If, within any selected time period (1 day, 1 week, 1 month), rainfall exceeds 7 inches (178mm) the measurement scale automatically changes to: in inches {0, 1, 3, 5, 10, 20, 30, 50, 100}; in millimeters {0, 10, 30, 50, 100, 300, 500, 1000}. The bar graph will display the rainfall history either by day, week, or month. The "DAY" icon will flash beside the "RAIN" icon at the top of LCD 5. Press the CH/+ button to toggle through the "WEEK, " "MONTH, " and "DAY" icons. Press the RAIN button (or wait 20 seconds) to confirm and exit this selection mode. If "DAY" is selected, the graph will display the rainfall history for the past 7 days. The information that is displayed in column "0" (the right column) is renewed daily at midnight, and the information contained in the columns is shifted to the left. If "WEEK" is selected, the graph will display the rainfall history for the past 7 weeks. The information that is displayed in column "0" is renewed every Monday at midnight, and the information contained in the columns is shifted to the left. If "MONTH" is selected, the graph will display the rainfall history for the past 7 months. [. . . ] 25 Outdoor humidity: Rain quantity: Every 10 seconds for the first 12 minutes, then every 5 minutes. Every 10 seconds for the first 12 minutes, then every 5 minutes. Sensor reading update Outdoor temperature: Outdoor humidity: Rain quantity update (Rain Gauge): Transmission frequency: Transmission range: Power supply Weather Center: Thermo Hygro Sensor: Rain gauge: Dimensions (L x W x H) Weather Center: Thermo Hygro Sensor: Rain Gauge (diameter x H): Every 1 minute. 2 x AA (IEC LR6) 1. 5V batteries. 9. 36 x 1. 56 x 23. 4 inches (240 x 40 x 600 mm). 5. 07 x 7. 41 inches (130 x 190 mm). 26 WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS-7095UM




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS-7095UM will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.