User manual LA CROSSE TECHNOLOGY WS8615

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS8615. We hope that this LA CROSSE TECHNOLOGY WS8615 user guide will be useful to you.


LA CROSSE TECHNOLOGY WS8615 : Download the complete user guide (243 Ko)

You may also download the following manuals related to this product:

   LA CROSSE TECHNOLOGY WS8615 (461 ko)
   LA CROSSE TECHNOLOGY WS8615 (458 ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS8615

Detailed instructions for use are in the User's Guide.

[. . . ] WIRELESS 433 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this revolutionary 433MHz temperature Station which provides advanced data-logging and data-analysis functions for up to three outdoor temperature readings. The temperature station is connectable to PC by the COM port and data importing to PC is allowed. By applying the smart software provided, user may perform data analysis and statistics conveniently in PC. With easy to use keys, this innovative product is ideal for home and professional usages. FEATURES: The Temperature Station Hanging Hole LCD screen Battery Compartment Function keys Cable socket (to PC) Foldout stand 1 · · · · · · · · · · · · · · · · DCF radio controlled time with manual setting option Time zone option ±12 hours Indoor and outdoor temperature display with MIN/MAX records and time of reception Indoor and outdoor humidity display as RH% with MIN/MAX records Data logging function ­ can store up to 3000 sets of Temperature/Humidity data Connectable to PC (Com port) ­ data can be transferred to PC with the software (in CD ROM) provided Can receive up to 3 outdoor transmitters Time reception ON/OFF selectable Dew point temperature displayed Temperature & humidity High/Low alarm function 12/24 hour time display Year/ Month/ Day calendar display Temperature display in ºC/ ºF LCD contrast selectable Low battery indicator Table standing or wall mounting The Outdoor Temperature Transmitter · · · · Remote transmission of outdoor temperature and humidity to Temperature Station by 433 MHz Shower proof casing Wall mounting case Mounting at a sheltered place. [. . . ] Press the SET key one more time to confirm and go back to the normal display mode. Note: · If user has set "Enr = 2" and three transmitters are on, the data only from channel No. 1 and 2 will be saved in the system memory. 19 · · On the other hand, if user has initially applied 3 transmitters but then remove the Channel 2, the temperature station will thereafter display "--. -" for Channel 2. And if the user has chosen "Enr = 2, then data from Channel 1 to 2 will be stored in the memory, instead of Channel 1 and 3. After the "Enr" number has been changed, the history data will be cleared and "mem" will be reset to "0000". TO EXIT THE MANUAL SETTING MODE Press the Mode key or Alarm key to exit the manual setting mode anytime during the manual setting. The mode will return to the normal time display. TOGGLING BETWEEN DIFFERENT CHANNELS (INDOOR AND OUTDOOR CHANNELS): 1. Press the Plus or Minus key to toggle between the Temperature and humidity readings of the indoor channel and the outdoor transmitter channel(s). The channel identification icon ("in", "out 1", "out 2", "out 3") will be displayed at the upper right screen indicating that the particular channel is now being selected. The temperature and humidity readings of Outdoor transmitter No. 1 is now shown 20 VIEWING VARIOUS TYPE OF TEMP/HUMDITY READINGS OF A SELECTED CHANNEL: After a particular channel (the indoor sensor or one of the outdoor transmitters) has been selected by pressing the Plus or Minus key, the following modes of data may be viewed by user: a. The Max temperature and Max humidity Max icon flashing In normal display mode, press the mode key once. The maximum temperature and maximum humidity measured by the channel, and the date and time of the maximum temperature recorded will be displayed. The "max" icon will be flashing. 21 b. The Min temperature and Min humidity Min icon flashing In normal display mode, press the mode key two times. The minimum temperature and humidity measured by the channel, and the date and time of the minimum temperature recorded will be displayed. The "min" icon will be flashing. 22 c. The average value of the last 100 sets reading Average icon flashing In normal display mode, press the mode key three times. The average temperature and humidity value of the data which have been saved in the system memory will be displayed. If the channel is not set to be saved in the system memory, no average value will be estimated and "--. -" will be shown. Note: The "Average" value displayed for particular channel will be calculated from only the new data being recorded after battery change. 23 d. The dew point temperature Dew point temperature icon In normal display mode, press the mode key four times. The dew point temperature will be displayed next to the flashing "td" icon. 24 e. The history data sets of temperature and humidity History data icon flashing In normal display mode, press the mode key five times. The "hist" icon will be flashing and the last recorded temperature and humidity reading with the time of record will be displayed. By pressing the Minus key, the previous sets of readings which were measured at the userselected recording intervals may be viewed. If the channel is not set to be saved in the system memory, no history values will be displayed and "--. -" will be shown on LCD. ALARM PROGRAMMING FOR INDOOR/ OUTDOOR TEMPERATURE AND HUMIDITY The weather station will allow users to set a range of specific alarms to meet specific temperature and humidity conditions set by the user. For example, user may set the high and low temperature alarm point at 30 and 20 °C respectively. Then the alarm will sound once the temperature is higher than 30. 0 or lower than 20. 0 °C. 25 To set the high humidity alarm: 1. [. . . ] the unit is attached to a piece of metal, it may either reduce or increase the transmitting range. For this reason, we recommend not placing the unit on any metal surfaces or in any position where a large metal or highly polished surface is in the immediate proximity (garage doors, double glazing etc. ). Before securing in place, please ensure that the Temperature Station can receive the signal from the Outdoor Temperature transmitter at the positions that you wish to situate them. CARE AND MAINTENANCE: · · · · · · Extreme temperatures, vibration and shock should be avoided as these may cause damage to the units and give inaccurate forecasts and readings. Do not use solvents or scouring agents as they may mark the LCD and casings. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS8615




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS8615 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.