User manual LIFT-MASTER FDC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER FDC. We hope that this LIFT-MASTER FDC user guide will be useful to you.


LIFT-MASTER FDC : Download the complete user guide (1230 Ko)

Manual abstract: user guide LIFT-MASTER FDC

Detailed instructions for use are in the User's Guide.

[. . . ] LM PL C C OWNER'S MANUAL MODEL FDC ADVANCED LOGIC INDUSTRIAL DUTY FIRE DOOR OPERATOR US PATENT NO. 6, 014, 307 O N TR O LMPLC CONTROL WIRED L B2 Wiring 2 YEAR WARRANTY Serial # (located on electrical box cover) Installation Date Wiring Type NOT FOR RESIDENTIAL USE 41B6 LISTED DOOR OPERATOR SPECIFICATIONS DRIVE SYSTEM GEAR REDUCERS:. . . . . . . . . . . . . . . . . . . . Helical inline, oil bath permanently lubricated, non-vented. CONTINUOUS POWER RATING: 1/2 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 ft-lbs/sec 1 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 ft-lbs/sec RATIO: 1/2 Hp: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48. 8:1 1 Hp: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49. 8:1 OUTPUT SPEED 1/2 HP:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 rpm 1 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 rpm OUTPUT TORQUE 1/2 HP:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 929 in-lbs. 1/2 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1" 1 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/4" OUTPUT SPROCKET 1/2 HP:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #50-14T 1 HP: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . #60-14T MAX. [. . . ] COIL CORD: Connect operator end of coil cord to junction box (not supplied) fastened to the wall approximately halfway up the door opening. LIMIT SWITCH ADJUSTMENT MAKE SURE THE LIMIT NUTS ARE POSITIONED BETWEEN THE LIMIT SWITCH ACTUATORS BEFORE PROCEEDING WITH ADJUSTMENTS. BE CERTAIN THAT DIP SWITCH #2 IS IN THE "OFF" POSITION (CDO MODE) BEFORE MAKING ADJUSTMENTS. To adjust limit nuts depress retaining plate to allow nut to spin freely. After adjustment, release plate and ensure it seats fully in slots of both nuts. Adjust open limit nut so that door will stop in open position with the bottom of the door even with top of door opening. Adjust close limit nut so that actuator is engaged as door fully seats at the floor. Close) Limit Switch SPARE Limit Switch WARNING TO AVOID SERIOUS PERSONAL INJURY OR DEATH FROM ELECTROCUTION, DISCONNECT ELECTRIC POWER BEFORE MANUALLY MOVING LIMIT NUTS. If other problems persist, call our toll-free number for assistance - 1-800-528-2806 Actuator RPM Board (Shown as LEFT Hand Unit) Rotator Cup Depress Plate OPEN Limit Switch 7 CLOSE Limit Switch NOTICE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. INSTALLATION MODE The motor operator installs as a standard commercial operator with standard wiring functionalty. Once installation is completed and all alarm devices are connected, and tested, the operator is then switched (DIP switch 2) to Fire Door Mode. Upon completion of installation, the units functionality should be checked by activating the key test station. If for any reason your unit does not respond as described in this manual, check that you have read and followed all installation and operating instructions. 1-800-528-2806. WARNING IT IS THE END USERS SOLE RESPONSIBILITY TO CHECK THAT ALL SYSTEMS ARE INSTALLED AND FUNCTIONAL. THE MOTOR OPERATOR MUST BE SWITCHED TO THE "FIREDOOR" MODE TO ENABLE ALL ALARM, AND WARNING SYSTEMS. DIP SWITCH #2 MUST BE SWITCHED TO THE "ON" POSITION TO ENABLE THE "FIREDOOR" MODE. FAILURE TO DO SO, COULD RESULT IN LOSS OF LIFE AND PROPERTY. Alarm Inputs: Alarm Input #1: Used for electronic alarm devices such as smoke detection devices or similar alarm systems. This alarm will activate a motored closure of the door, and all sensing and control devices will remain active. It is imperative that the alarm signal contact is maintained for a time period greater than the alarm delay to close setting. If dip switch #1 is in the "OFF" position (10 seconds) the alarm system must supply a "DRY" contact signal to terminals J2-11 & J2-12 for a minimum of 12 seconds. Alarm Input #2: Used for the thermal sensors (electronic fusible links) or similar systems. state only) This alarm condition will activate a motored closure of the door, and all sensing devices and control stations will be rendered inactive. [. . . ] Check wires to safety edge, or infrared safety eyes, if unit is equipped with a safety to reverse feature. Generally inspect the motor mounting, and tighten the fasteners and bracing. Verify that all conduit connections are tight and have no exposed wires. Compare readings to those listed on the motor nameplate. 16 MOTOR OPERATOR TROUBLE SHOOTING GUIDE SYMPTOM POSSIBLE CAUSE REPAIR Check circuit breaker, power fuses, safety switch; check cause. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER FDC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER FDC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.