User manual LIFT-MASTER LM21

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER LM21. We hope that this LIFT-MASTER LM21 user guide will be useful to you.


LIFT-MASTER LM21 : Download the complete user guide (239 Ko)

Manual abstract: user guide LIFT-MASTER LM21

Detailed instructions for use are in the User's Guide.

[. . . ] Overhead Door Corporation Pennsylvania Division 23 Industrial Park Road Lewistown, Pennsylvania 17044 Phone: (800) 929-2553 (717) 248-0131 Fax: (717) 248-6447 Installation Manual Addendum MODELS FSXP-FLR FSXPBB-FLR FSXPBBVB-FLR FIRE SENTINEL FLOOR RESET Reset Mechanism Installation and testing to factory specifications shall be performed by factory authorized personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), local, state, county, district and/or other applicable building and fire standards, guidelines, regulations and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. NEVER connect release device to power source until instructed to do so. DO NOT install this device on a motorized door without an electric safety edge. [. . . ] An eyebolt installed at a distance of 18" to 24" from the release device should adequately redirect sash chain. Reset cable mounting box should be mounted with minimum #6 size fastening screws/bolts for surfaces other than masonry. For masonry applications use 1/4" or greater anchors or studs as required for proper mounting strength. Make sure release device/reset is in released position (Figure 3) and cable is fully pushed in with reset handle seated the against jam nut. When using solid cable, refer to manufacturer specified bend radius restrictions. Secure cable at 36" maximum spacing using suitable 3/16" cable clip or clamp (Figure 3). See door manufacturer recommendations and NFPA 80 for use of this product with specific door. INSTALLATION INSTRUCTIONS ADDENDUM Installation procedures, and door manufacturer instructions, must be followed to assure performance of the release device/reset mechanism to factory standards. To be performed by factory authorized personnel only. MOUNTING PROCEDURE (Figure 1) 1. The release device shall be mounted on a vertical surface with chain end link exiting side of enclosure. Secure the release device enclosure with fastener (#10 is the minimum size recommended). TYPICAL INSTALLATION FIGURE 1 End Link Releasing Device with Reset Mechanism Fuse Link, Sash Chain or Cable Smoke Detector Grifco Fire Door Hoist Optional Signal Appliance Tamper Resistant Reset Handle RELEASING DEVICE TEST / RESET PROCEDURES NOTE: To be performed by factory authorized personnel only. The following test/reset procedure applies to all release devices using the reset mechanism. These procedures are supplemental to test procedures provided in the release device manual. Testing affects normal operation of central alarm system when connected to release device. Testing and normal operation can only be accomplished with power applied to unit. When power is applied to unit under test, the "Power" LED (red) will be lit on the release device. [. . . ] Installer shall provide the following information when contacting technical support: · · · · · · · Serial Number, found in the following locations Individual unit shipping box Cover of installation manual On unit Name of Distributor who supplied product Name of End User and/or installation company if different from Distributor Detailed description of product non conformity To receive a Return Goods Authorization (RGA) and shipping address for a product believed to be defective, all of the above information shall be required. If provided, reference troubleshooting guide that accompanies product prior to requesting an RGA. Contact Information Technical Support: 1-800-929-2553 01-30632 Issue Date 8/18/2006 © 2006, The Chamberlain Group, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LM21




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LM21 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.