User manual LIFT-MASTER MIRACLE ONE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER MIRACLE ONE. We hope that this LIFT-MASTER MIRACLE ONE user guide will be useful to you.


LIFT-MASTER MIRACLE ONE : Download the complete user guide (6364 Ko)

Manual abstract: user guide LIFT-MASTER MIRACLE ONE

Detailed instructions for use are in the User's Guide.

[. . . ] TABLE OF CONTENTS Attention: This handbook is exclusively for qualified installation personnel, and assistance and/or maintenance service. - The performances indicated in this handbook are valid only if a correct assembly has been carried out. UL Listings and Instructions Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Swing Gate Systems Warnings and Precautions "Open to the Inside" Mounting Specifications "Open to the Outside" Mounting Specifications Step-by-Step Operator Mounting Instructions Removing the Control/Surge Suppressor Boards Mounting the Control Box Wiring 1 Operator to the Surge Suppressor Board Wiring 2 Operators (Master/Second) to the Surge Suppressor Board Choosing Gate Movement Direction Sensor Adjustment Adjustable Timer Earth Ground Rod Installation Connecting Power Supply Wiring Additional Inputs Single Operator Loop Size and Placement Master / Second Loop Size and Placement Loop Installation and Number of Wire Turns Loop Detector Wiring Photocell Installation Single Control Board Description Master / Second Control Board Description Surge Suppressor Board Description Alarm / Maglock Control Board Connections UL Audio Alarm Burglar Alarm and Proximity Switch "Gate Opening Inside" Installation of Maglock / Solenoid Relay "Gate Opening Outside" Installation of Maglock / Solenoid Relay Close Delay Option (Master / Second Only) Emergency Key Release Troubleshooting Optional Solar Power Miracle 1 Accessories Miracle 1 Parts Illustration Miracle 1 Parts List / Maintenance Features and Specifications Quick Reference Surge Suppressor Wiring Diagram 2-5 6 6 7 7 8 9 10 11-14 15 15 16 17 18 18 19 19 20 21 22 23 24 25 26 27 28 29 30 31 31 32 33 34-35 36 37-39 40 41 42 43 45 46-47 Please DO NOT Touch me!. . . Unless you are an Authorized Service Technician! © 1998-2004 by Chamberlain Professional Products All rights reserved. [. . . ] After completing all the electrical connections, continue to step 11 to complete the final adjustments on the operator. 13 PROCEDURE FOR INSTALLATION Adjusting the Limit Switches Step 11: Adjust the travel distance of the gate with the limit switches. Position the outside limit switches of each armature to stop the gate in the "full open" and "full closed" positions. Re-tighten armature screws when gate positions are correct. Outside Limit Switch Inside Limit Switch Limit Switch Armature Adjustment Screws Inside Limit Switch Outside Limit Switch Adjustment Screws Limit Switch Armature Step 12: Reinstall the operator cover with the 4 screws to complete the installation. 14 REMOVING THE CONTROL / SURGE BOARDS Unscrew the 4 Phillips head screws from the cover. Unplug all accessory wires from Surge Suppressor's removable terminals. 7 Remove three Phillips screws from surge suppressor board and remove board. 1 2 3 4 1 1 1 MAGLOCK ALARM SYSTEM ON REVERSE SENSOR ALARM SENSOR OPEN OUTSIDE OPEN INSIDE STOP BY POSITIVE STOP REPLACE FUSE WHEN LED IS ON NO OFF 60 YES ON 3 POWER CHARGE OK BATTERY LOW TIMER CENTRAL CONTROL 6 ® ACCESS SYSTEMS INC RADIO CENTER STRIKE SAFETY REC LOOP OPEN LOOP MIRACLE SURGE PROTECTION ® MIRACLE SURGE PROTECTION ® LAKE FOREST, CALIFORNIA LAKE FOREST, CALIFORNIA www. eliteaccess. com www. eliteaccess. com REV A 2 SLAVE ONLY UL SENSOR BURGLAR ALARM INPUT +24 VOLT GROUND CENTER LOOP MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE LIMITS GREEN BLUE SAFETY LOOP BROWN RADIO EXIT LOOP 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 2 +24 VAC INPUT 8 REV A BLACK WHITE RED 3 BURGLAR ALARM INPUT SINGLE OR MASTER ONLY MOTOR BRAKE +24 VOLT GROUND CENTER LOOP MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 1 2 3 26 27 4 4 MOUNTING Caution: THE CONTROL BOX Do Not make new mounting holes, or enlarge existing holes in control box. Use the four mounting holes provided. Remove the four nuts and remove battery rack. Reverse this process to reinstall. Mount control box with four screws and washers (recommend #10 thru 1/4-20 Bolts or Screws) Do Not over tighten. 15 +24 VAC INPUT SAFETY LOOP RADIO EXIT LOOP 5 SINGLE OR MASTER ONLY SLAVE ONLY 7 27 WIRING MIRACLE SURGE PROTECTION ® 1 OPERATOR TO BOARD LAKE FOREST, CALIFORNIA www. eliteaccess. com Caution: Do Not over-bend the cord from the operator. Doing this will cause the wires to eventually break. REV A Caution: Do Not use wire less than 16 gauge up to 200 Ft. Removable Terminal Connector +24 VOLT GROUND Wire SINGLE OR MASTER ONLY MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK SECOND ONLY BURGLAR ALARM INPUT CENTER LOOP MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR +24 VAC INPUT 26 27 SAFETY LOOP RADIO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Caution: Make sure BARE WIRE 24 EXIT LOOP 25 Removable Terminal Connector makes good contact inside removable terminal connectors. DO NOT let wire insulation interfere with connection. 1 Black 2 White 3 Red 4 Brown 5 Blue 6 Green Important: Install the Conduit (supplied) to secure the wire to the Miracle 1 Control Board Box. If the conduit can not be used, Install a dedicated water tight conduit for 6 wires. More than 20 ft run, you MUST use Shielded Wire for the blue and green lines. Shield must be grounded. MIRACLE SURGE PROTECTION ® LAKE FOREST, CALIFORNIA www. eliteaccess. com 8 REV A SINGLE OR MASTER ONLY MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK SECOND ONLY BURGLAR ALARM INPUT +24 VOLT GROUND CENTER LOOP MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR +24 VAC INPUT 26 27 SAFETY LOOP STRIKE INPUT RADIO 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 Supplied Conduit 16 WIRING 2 OPERATORS MASTER / SECOND MIRACLE SURGE PROTECTION ® LAKE FOREST, CALIFORNIA www. eliteaccess. com 6 Wires, 16 AWG from operator in dedicated water tight conduit. Operator 2 (Second) Water Tight J-Box Kit Elite # K55-09853 REV A Operator 1 (Master) Caution: Do Not use wire less than 16 gauge up to 200 Ft. SINGLE OR MASTER ONLY MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK SECOND ONLY BURGLAR ALARM INPUT +24 VOLT GROUND CENTER LOOP MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR +24 VAC INPUT 26 27 SAFETY LOOP RADIO 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 www. eliteaccess. com ® 20 21 EXIT LOOP 22 23 25 MIRACLE SURGE PROTECTION LAKE FOREST, CALIFORNIA Removable Terminal Connectors REV A SINGLE OR MASTER ONLY MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK SECOND ONLY BURGLAR ALARM INPUT +24 VOLT GROUND MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR CENTER LOOP +24 VAC INPUT 26 27 SAFETY LOOP STRIKE INPUT RADIO 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 1 Black 2 White 3 Red 4 Brown 5 Blue 6 Green 7 Black 8 White 9 10 11 12 Brown Shield Green Blue Red Supplied Conduit Important: Master Removable Terminal Connector Second Install the Conduit (supplied) to secure the Master Operator to the Control Board Box. More than 20 ft run, you MUST use Shielded Wire for the blue and green lines. Shield must be grounded. Wire Supplied Water Tight Conduit (Not Supplied) Caution: Make sure BARE WIRE makes good contact inside removable terminal connectors. DO NOT let wire insulation interfere with connection. 17 CHOOSING GATE MOVEMENT DIRECTION Switch the "Open Inside / Open Outside" switch on the control board to the corresponding position for the proper direction. 8 The gate opens inward. The gate opens outward. SENSOR ADJUSTMENT Caution: The sensors must be adjusted while the gate is in the opening or closing cycle. Adjusted by Qualified Service Personnel Minimum Sensitivity 8 Maximum Sensitivity Set the sensor adjustment so when the gate hits any object while opening, it will stop and when the gate hits any object while closing, it will reverse. Option ­ Stop by Positive - Stop This option is to be turned to "yes" if the gate will use positive stops at the close position. Note: If you activate the operator and the gate stops in the middle of the driveway, the sensor is set too sensitive. Important: It is necessary to still adjust your limit switch at the close position. The controller will look for the limit close first and then it will look for the positive stop. 18 ADJUSTABLE TIMER Timer On Set Timer 1 to 60 Seconds Timer Off If secondary safety sensor devices are not used when timer is ON, gate will hit vehicle obstructing gate path. EARTH GROUND ROD INSTALLATION Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into the earth. Without this path, the intense energy generated by lightning could be directed towards the Elite gate operator. Although nothing can absorb the tremendous power of a direct lightning strike, proper grounding can protect the gate operator in most cases. The earth ground rod must be located within 3 feet from the gate operator. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length. Connect ground wire to green wire from surge suppressor board Use 12 gauge ground wire Before digging more than 18" deep, contact local underground utility locating companies Avoid damaging gas, power, or other underground utility lines. Chamberlain Professional Products is not responsible for improper installation or failure to comply with all necessary local building codes. 19 REV A CONNECTING POWER SUPPLY Connect Elite's plug-in transformer (24 VAC Included) to Surge Suppressor board, terminals #26 and #27. [. . . ] The radio receiver has malfunctioned in the "ON" position. Control Board LED The Gate Will Not Open! Symptom: The radio receiver LED on the control board remains "OFF" when using the remote control. Remote control code switches are different from radio receiver code switches. The radio receiver has malfunctioned in the "OFF" position. CENTRAL CONTROL Possible Solutions: Control Board LED 38 TROUBLESHOOTING You will SEE the alarm LED "ON" when. . . SYSTE ON SE REVER R SENSO For Toll Free Technical Support: 1-888-ELITE-10 M ALARM R SENSO Horizontal Gate Level line Vertical Gate Level line Incorrect Installation 1 The gate is too heavy or the operator or gate is installed incorrectly. 2 A foreign object is on the gate frame while the gate is moving. 3 Gate hinges are too tight or broken and the gate is not moving freely. 4 The gate hits the driveway, curb or other, and gets stuck in an awkward position. 39 OPTIONAL SOLAR POWER Elite offers a plug-in solar adapter and solar panel as an option for the Miracle 1. Elite's "SOLAR 3" solar panel provides solar power for the Miracle 1 single and double arm operators. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER MIRACLE ONE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER MIRACLE ONE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.