User manual NIKON NIKKOR ED 300MM F/2.8 IF

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NIKON NIKKOR ED 300MM F/2.8 IF. We hope that this NIKON NIKKOR ED 300MM F/2.8 IF user guide will be useful to you.


NIKON NIKKOR ED 300MM F/2.8 IF : Download the complete user guide (12717 Ko)

Manual abstract: user guide NIKON NIKKOR ED 300MM F/2.8 IF

Detailed instructions for use are in the User's Guide.

[. . . ] MOUNTING THE LENS A To mount, position the lens in the camera's bayonet mount, lining up the aperture index on the lens with the lens mounting index on the camera. To remove, press the lens release button on the camera and turn the camera body counterclockwise. Note: When the lens is used with the Nikon F-401/N4004*, the camera meter coupling function does not operate and the exposure indicator LEDs do not appear. [. . . ] E] 'E 2 F 12 RECOMMENDED FOCUSING SCREENS Various interchangeable focusing screens are available for F3- and F2-series cameras to suit any type of lens or picture-taking situation. For screens used with Nikon cameras other than F3and F2-series cameras (e. , Nikon FA, FE2, FM2 and FE), refer to the column for F3series cameras. For the K2, B2 and E2 focusing screens, refer to the columns on the K, B and E screens, respectively. For details, also refer to the specific focusing screen's instruction sheet. ^ ^ ~ Screen Camera '—-—^__ A/L B C D E G1 G2 G3 G4 HI H2 H3 H4 J K/P M R T U F3 F2 © © © O © o o o c D © © o o o o G1 G2 G3 G4 HI o o H2 © © o o H4 © © © © 0 © 0 © • When the Teleconverter TC-14A is attached to this lens, use the following table*: ~~ — — ^ _ _ ^ Screen Camera —-—__ A/L B E H3 J K/P M R T U F3 F2 © © © O © O o o © © © © © © 0 © © © • When the Teleconverter TC-14B or TC-14 is attached to this lens, use the following table: "— — Camera Screen -——-_^ A/L B C D E Gl G2 G3 G4 HI H2 H3 H4 J K/P M R T U F3 F2 © © © © o o o 0 <(» (Q) o O © © © © © © 0 © • When the Teleconverter TC-201 or TC-200 is attached to this lens, use the following table*: •*—--. Camera Screen •—-—_ °l o o o HI A/L B C D E Gl G2 G3 G4 H2 H3 H4 J K/P M R T U F3 F2 (» © • © o 0 o o © © O © © • ® © • © 3 o • When the Teleconverter TC-301 or TC-300 is attached to this lens, use the following table: ~~~~~~—-—^ Camera Screen ~-~—_„ A/L B C D E Gl G2 G3 G4 HI H2 H3 H4 J K/P M R T U F3 F2 • • © © o o o o © (, ») o o o o © © • # © • © © * Usable, but vignetting or otherjmage deterioration may occur. €¢ = Exposure measurement not possible Lens/screen combination permits only focusing operation. 8 Lens construction: 8 elements in 6 groups (plus dustproof glass plate built into front) Picture angle: 8" 10' Distance scale: Graduated in meters and feet from 3m (10 ft) to infinity (•») Aperture scale: f/2. 8 ~ f/22 on both standard and aperture-direct-readout scales Diaphragm: Fully automatic Exposure measurement: Via full-aperture method; meter coupling ridge provided for AI cameras and meter coupling shoe for non-AI cameras Focusing: Nikon Internal Focusing (IF) system Infrared focusing index: Provided Tripod mounting: Built-in tripod mounting collar rotatable through 360° Lens hood: Built-in Telescopic screw-out type Extension lens hood: Provided Filters: Slip-in type glass filter holder accepts 39mm dia. 2400g Accessories Slip-on leatherette front lens cap Rear lens cap LF-1 Extension lens hood HE-4 Built-in 39mm screw-in filter L37C Gelatine slip-in filter holder Heavy-duty case CT-302 39mm screw-in filters Teleconverter TC-14A Teleconverter TC-14B Teleconverter TC-201 Teleconverter TC-301 LENS CARE • Although you should always keep the lens surfaces clean, rough cleaning must be avoided. Wipe with a soft, clean cotton cloth moistened with alcohol tq remove grease or fingerprints from the lens surfaces. If you use ether in cleaning the lens, a smudge sometimes appears on the surface of a multi-coated lens. If this happens, wipe it again with a cotton cloth moistened with alcohol. [. . . ] 9 •The first values are for the Kl ring used alone and the second ones for five rings used together. "The first values are for the PK-11 A or PK-t ring used alone and the second ones for three rings (PK-11A- PK-13 or PK-1-PK-3) used together. * Grace a un systeme de mise au point interne (IF), la distance de mise au point de cet objectif est plus courte que celle de modeles anterieurs a mise au point helico'idale, pour une distance t'ocale identique. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NIKON NIKKOR ED 300MM F/2.8 IF




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NIKON NIKKOR ED 300MM F/2.8 IF will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.