User manual PALSONIC AAC90CW

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PALSONIC AAC90CW. We hope that this PALSONIC AAC90CW user guide will be useful to you.


PALSONIC AAC90CW : Download the complete user guide (244 Ko)

Manual abstract: user guide PALSONIC AAC90CW

Detailed instructions for use are in the User's Guide.

[. . . ] ROOM AIR CONDITIONER OWNER'S MANUAL How to use . . . . . . . . . . . . . . . . . . . . . P. 7~P. 10 AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL: (02) 9313 7111 FAX: (02) 9313 7555 www. palsonic. com. au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA: 1300 657 888 Thank you for purchasing our air-conditioner. Please read this owner's manual carefully before using your air conditioner. How to Use NAMES OF THE PARTS Front Cover Air inlet grille (Indoor) Cabinet Air outlet grille (Indoor) Air inlet grille (Outdoor) Vent Lever Control Panel (Show in page 4) Cover Control Panel (behind panel cover) Spice box (Used in some type of air conditioner) Air filter Fig: 1 NOTE In quiet operations or stopping the operation, the following phenomena may occasionally occur, but this is normal for operation. [. . . ] Turn the lever "OPEN" to close vent. CAUTION Usually this lever is kept at "CLOSE" position (left). Turn the lever "CLOSE" to close ventilation in case of typhoon. 3 Names and Functions of remote controller (ONLY APPLICABLE FOR REMOTE CONTROL TYPE) Mode display: Cool - Dry - Fan Set Temperature Display Fan speed display HI - LOW Mode selection key Setting for increasing of temperature Setting for decreasing of temperature Fan speed setting up key Vane setting key Hour setting for timer or clock Minute setting for clock Sleep setting up key Air flow Display SWING - STOP Clock display Sleep Display On-timer or Offtimer, time display Power on/off key Timer setting up key Emergency run operation The ON/OFF button operations ON/OFF of the unit temporarily when remote controller is not used. Pressed once, the air-conditioner start operation, the method of operation is in AUTO. and the FAN indicated continue the Timer cancel, pressed again, the air-conditioner stopped In COOL /DRY/FAN/AUTO model, the green lamp light. THE WINDOW OF INDICATION 4 AIR FILTER The air filter should be washed at least once every 20 days. If the air filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced. The filter is behind the cover and to be pulled out from right hand side. 4 CAUTION Do not use hot water above 400C for washing the air filter. Do not operate the air conditioner with the filter removed. AIR CLEANING FILTER The air cleaning filter is attached to the air filter Wash the air cleaning filter as well when wash air filter. . FRONT COVER, ETC The front cover will accumulate dirt and dust. When it is excessively dirty, wipe it with a soft cloth dampened with warm water or mild soap, then wipe it again thoroughly with a soft dry cloth. Hot Water Benzene, acid, etc. 5 Never use hot water above 500C, benzene, gasoline, acid, thinner or brush to wipe off dirt because they will damage the plastic surface and the coating. LONG OFF PERIOD MAINTENANCE Operate the fan alone ("LOW FAN "or "HIGH FAN") for half a day to dry out the inside of the unit. After a long off period and going to use the air conditioner again , clean the CONDENSER (at the rear) and EVAPORATOR (at the front) fins by using a soft brush or vacuum cleaner. CAUTION Be careful not to damage the fins during the cleaning. BEFORE ASKING FOR SERVICE Check the following points before requesting for repairs or service. If the malfunction persists, please contact our customer service. Faults Does not operate Cause 1 2 3 4 1 Is the power off?The doors or windows may be opened widely or there are other sources of heat in the room?Is the ventilation damper opened? 2 3 Does not cool effectively 4 5 6 6 Installation Instruction REMOVE ALL THE SHIPPING PARTS BEFORE INSTALLATION LOCATION Select a location that can support the weight of the air conditioner and one that will not cause increased operation noise and vibration. Select a place where there is no obstacles near the air inlet and outlet. Less than C More than D Scrape If the wall thickness is more than C scrape the wall as shown above. wall thickness is less than C Make rear side lower so that water will drain out smoothly. Fig. 5 Capacity dimension A B C D 7000Btu/h 9000Btu/h 400 500 170 50 12000Btu/h 400 500 210 60 18000Btu/h 24000Btu/h 400 500 210 55 7 Less than C CAUTION The installation parts must be strong against corrosion, especially in case the air conditioner will be installed near the sea or hot spring. Do not install air conditioner in the place where inflammable gas leaks are a possibility. OPERATION Check the capacity of wiring and power outlet. [. . . ] 16) Fig. 10 Retaining bracket Fig. 9 Fig. 8 Wall Cabinet Screw Installation shelf Fig. 12 Fig. 11 9 Fig. 16 10 ATTENTION Welcome to this family of air Conditioner owners. Air conditioner is a valuable commodity and we highly recommend that you use the services of experienced specialist to install the unit, Otherwise it will not only result in economic losses, but also affect the operations and efficiency of this Unit, It will not be held responsible for only breakdown if this unit is not installed properly, AIRMASTER 1 JOYNTON AVENUE WATERLOO NSW 2017 AUSTRALIA TEL: (02) 9313 7111 FAX: (02) 9313 7555 www. palsonic. com. au AIRMASTER CUSTOMER SERVICE TELEPHONE AUSTRALIA: 1300 657 888 AAC70CW AAC90CW [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PALSONIC AAC90CW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PALSONIC AAC90CW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.