User manual PANASONIC WH-SHF09F3E5

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC WH-SHF09F3E5. We hope that this PANASONIC WH-SHF09F3E5 user guide will be useful to you.


PANASONIC WH-SHF09F3E5 : Download the complete user guide (3790 Ko)

You may also download the following manuals related to this product:

   PANASONIC WH-SHF09F3E5 (744 ko)
   PANASONIC WH-SHF09F3E5 (3333 ko)
   PANASONIC WH-SHF09F3E5 (3333 ko)
   PANASONIC WH-SHF09F3E5 (3333 ko)
   PANASONIC WH-SHF09F3E5 (3333 ko)
   PANASONIC WH-SHF09F3E5 (3333 ko)
   PANASONIC WH-SHF09F3E5 (6595 ko)
   PANASONIC WH-SHF09F3E5 (3333 ko)

Manual abstract: user guide PANASONIC WH-SHF09F3E5

Detailed instructions for use are in the User's Guide.

[. . . ] 86-99 F569378 Table of contents Safety precautions …………………………… 3-5 To adjust initial settings ……………………… 6-7 How to use ………………………………… 8-12 Cleaning instructions ………………………… 12 Troubleshooting ……………………………13-14 Information …………………………………… 15 Thank you for purchasing Panasonic product. Before operating the system, read these operating instructions thoroughly and keep them for future reference. Before use, make sure the system has been installed correctly by an authorised dealer according to the given instructions. €¢ Panasonic Air-to-Water Heatpump is a split system, consisting of two units: indoor and outdoor units. [. . . ] 5 minutes ~ 14 Continuation of Sterilisation To maintain heating temperature in order to complete the sterilisation. 1 hour 15 Base Pan Heater To select whether or not to connect to the optional base pan heater. 16 Base Pan Heater type Type A - The base pan heater activates only during deice operation. 1 day ~ 99 days Do not use this menu for any other purposes and in period other than during construction (Refer to Information page). –  Note: • The current day and time need to be set in cases below: - When the power is turned on for the first time. - A long time has elapsed since the power was turned on the last time. €¢ The current time that has been set will be the standard time for all the timer operations. Caution Indicator (Tank Temperature above 60 °C) To adjust initial settings English 7 How to use User The system is turned off by an external switch. Turn on or off the system Press When the system is ON, the operation LED is lit and the actual water outlet temperature and outdoor ambient temperature are shown on the display. HEAT • The outdoor unit provides heat to the + TANK sanitary tank and indoor unit. €¢ This mode cannot be selected when the sanitary water tank is not installed. tANK • The sanitary water tank is either turned ON or OFF. €¢ The outdoor unit provides heat to the sanitary water tank. €¢ The backup heater provides extra heat at low outdoor temperature. €¢ Once the backup heater is set, it is automatically operated when conditions are fulfilled. 2 Press • Dry concrete (does not show during normal operation) • The Water Inlet Temperature • Tank Temperature • Compressor Running Frequency • Error History • Heat mode total power consumption (Up to 999 days) • Tank mode total power consumption (Up to 999 days) • Press to exit the STATUS mode. €¢ Once the STATUS mode is entered, the display shows STATUS. €¢ The STATUS mode cannot be activated when the display shows SETTING. €¢ The total power consumption is an estimated value based on AC 230 V and may differ from value measured by precise equipment. ■ Note: ■ Note: 8 In normal operation , the , and buttons are not in use. Dealer User Dealer Operation/settings to be done only by the authorised dealer/specialist. Operation/settings to be done by the authorised dealer/specialist or user. [. . . ] Operation starts automatically when the • Sterilisation timer has been set. Display power consumption remains • Memory is saved on hourly basis. If a power failure occurs, the data kept from last hour will be displayed. Loud refrigerant noise continue for a • It is caused by protection control during deice operation at outdoor ambient temperature lower than -10 °C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC WH-SHF09F3E5




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC WH-SHF09F3E5 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.