User manual QSC AUDIO DSP 322UA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual QSC AUDIO DSP 322UA. We hope that this QSC AUDIO DSP 322UA user guide will be useful to you.


QSC AUDIO DSP 322UA : Download the complete user guide (1094 Ko)

You may also download the following manuals related to this product:

   QSC AUDIO DSP 322UA DATASHEET 06-18-08 (211 ko)

Manual abstract: user guide QSC AUDIO DSP 322UA

Detailed instructions for use are in the User's Guide.

[. . . ] DSP 322ua 8x8 Signal Processor Hardware Manual *TD-000199-00* TD-000199-00 rev. B IMPORTANT SAFETY PRECAUTIONS & EXPLANATION OF SYMBOLS The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous" voltage within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to humans. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in this manual. This unit has been engineered and manufactured to assure your personal safety. Improper use can result in potential electrical shock or fire hazards. [. . . ] TX (transmit)- This indicator illuminates whenever the DSP 322ua transmits data onto the network. LINK STATUS- The corresponding indicator illuminates when the DSP 322ua is connected to an operating network. SIGNAL indicators- These indicators will illuminate green for input signals -40dB to -10dB below full scale; yellow for signals between -10dB to -2dB below full scale; red for -2dB to full scale (or clip). LCD Display and Controls The DSP 322ua has a 2 line X 16 character LCD display. The display and the multi-function push-button switches on either side provide data access and editing capability. The push-button switches on either side of the display are used to navigate through the menus. The rotary select/accept knob is active for many displayed items allowing you to scroll through choices by rotating the control, and accepting choices (entering) by pushing in on the control. The accessible menus and sub menus may appear differently than the example shown. The basic navigation flow for the DSP 322ua menu system is shown on the following page. Front Panel Password Lockout The password lockout provides the ability to restrict access to all of the editable parameters available on the LCD front panel. This feature is enabled or disabled via QSControl. net software only (refer to the "General Tab" area and click on the "Front Panel Password" button). When the lockout feature is enabled, all front panel LCD functions are readable, but editing of parameters is now password protected. While in this mode, any attempt to edit a parameter requires the user to enter the Front Panel Password. The password is stored in the DSP unit and can be changed using the QSControl. net software. Once the password has been correctly entered, the DSP will allow edits to the parameters. After 5 minutes of inactivity, the DSP will automatically reset the Front Panel Password lockout. The lockout mode can be deliberately disabled via the "Disable Edits" checkbox in the Front Panel Password menu of the QSControl. net software. 12 LCD Navigation Map Left side buttons have screen dependent functions. This read-only screen is the "out of the box" default display after power up. This is the most desired information when first setting up a network system. Once user moves to a different screen, the last screen accessed becomes the new power up default. Rotate to move cursor and push to accept change. Right side buttons serve as up/down navigation. If additional menus are available, the arrow character will be shown. *Note: After successful password entry, all screens with editable parameters will have read write capability. Without password entry, these screens will be read-only. 13 Getting Started This section outlines one of the simpler methods of getting familiar with your DSP 322ua and the QSControl. net software. The goal of this procedure is to get your computer and the DSP 322ua connected and communicating and the QSControl. net software installed and running. [. . . ] 3- Now you have the same options that are available in the Serial Port I/O (RS-232) interface section. 17 Preliminary Specification IN Dynamic Range (AES-17, -60dB Method, all sensitivities) unweighted >110dB A weighted >113dB Distortion (20Hz-20 KHz, all sensitivities) Gain= 0 - 30dB Gain >30dB Crosstalk (20Hz - 20KHz) inter-channel (max) inter-channel (typ) intra-channel (max) intra-channel (typ) Frequency Response 20Hz - 20KHz (max) 20Hz - 20KHz (typ) Program Inputs Connector Type Type Grounding Pinout Input Impedance (nom. ) Common-Mode Rejection E. I. N. (max. ) Input Sensitivities (variable) Phantom Power (per IEC1938 (1996)) Program Outputs Connector Type Type Grounding Pinout Maximum Output Level Audio Converters Mute Delay DSP 322ua in stand-alone mode Analog input through full DSP chain to analog outputs 2. 354 milliseconds (Default Group Delay) OUT >112dB >115dB THRU >108dB >111dB <0. 008% THD+N <0. 05% THD+N <0. 009% THD+N <0. 009% THD+N <0. 009% THD+N <0. 05% THD+N >75dB >90dB >85dB >100dB ± 0. 5dB ± 0. 2dB 8 3-pin "Phoenix Style" (a. k. a. "Euro Style") detachable terminal blocks Electrically balanced All shield terminals connected to chassis 1:+ 2:- 3:CHASSIS GND Balanced: 6. 81k ohms Unbalanced: 13. 6k ohms 20Hz - 20KHz (min. ): >54dB, 20Hz - 20KHz (typ. ): >60dB 150 ohm, 30dB: -124. 5dBu150 ohm, 60dB: -125. 0 dBu Vrms: 0. 9 mV to 15. 46 V dBu: -62. 2 to +26dBu dBV: -64. 4 to +23. 7 dBV +48V (software-selectable) 8 3-pin "Phoenix Style" (a. k. a. "Euro Style") detachable terminal blocks Electrically balanced All shield terminals connected to chassis 1:+ 2:- 3:CHASSIS GND 9V (rms ), +21. 2 dBu, +19 dBV 24 bit, 48KHz, in and out infinite attenuation Specifications are subject to change without notice. 18 Preliminary Specification Relay Outputs Connector Type Configuration Pinout Switching Capacity (nom) Logic Outputs Connector Type Configuration Pinout Omni Inputs Connector Type Configuration Pinout Normal Operating Range Potentiometer Operation Voltage Tolerance Current Output RS-232 Port QSControl. net Indicators QSControl. net Status Power Diagnostic LCD Data Display Signal Presence Dimensions Weight 2 discrete floating relay switch outputs 3-pin "Phoenix Style" (a. k. a. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE QSC AUDIO DSP 322UA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual QSC AUDIO DSP 322UA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.