User manual SAGEM TGR 350SG DATASHEET
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAGEM TGR 350SG. We hope that this SAGEM TGR 350SG user guide will be useful to you.
Manual abstract: user guide SAGEM TGR 350SGDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] DC jack The adapter must be in the range 5V~16V and can supply over 1. 5A.
b. DC power switch Switch to right direction to power on HiLoNC3GPS module and other function on the interface board. Otherwise, switch to left direction to power off all power including module and interface board.
Left
Right
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
5
c. [. . . ] Otherwise, switch to left direction to power off all power including module and interface board.
Left
Right
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
5
c. Primary RF in This is for the purpose of connecting interface board and base station (ex: CMU200, 8960, real antenna)
d. Diversity RF in This is for the purpose of connecting interface board and base station (ex: CMU200, 8960, real antenna)
e. GPS Antenna in This is for the purpose of connecting interface board and satellite.
f. USB This USB has two main function: download firmware send AT command
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
6
g. The audio generator can output a tone to HIALLNC module through this jack.
h. Audio in (Mic) The purpose is the same as item "g" and we can switch the audio path by different location of jumps (JP4/JP6).
i. For the new version of interface board , In case of shorting the jump (location P8) , the module will power on automatically.
j. 1. 8V power supply to JTAG (HiLoNC3GPS)
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
18
3. 10 VIO_SEL (for HIALLNC only) JP5. 1 short to JP5. 2 VIO_SEL=HiZ . JP5. 2 short to JP5. 3 VIO_SEL=0
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
19
3. 11 UART1 level shifter JP10. 1 short to JP10. 2 Under the condition of HIALLNC VIO_SEL=HiZ , put the jumps on JP10 pin1/2 to select 2. 8V voltage supply. JP10. 2 short to JP10. 3 put the jump on JP10 pin2/3 for HiLoNC3GPS.
JP11
For HiLoNC3GPS, keep JP11 open. For HIALLNC (VIO_SEL=0), put jump on JP11.
JP12
For HiLoNC3GPS, keep JP12 open. For HIALLNC (VIO_SEL=0), put jump on JP12.
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
20
JP10
JP11
JP12
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
21
3. 12 UART0 level shifter (for HIALLNC RTC/CTS only) JP14. 1 short to JP14. 2 Under the condition of HIALLNC VIO_SEL=HiZ , put the jumps on JP14 pin1/2 to select level shifter 2. 8V voltage supply. JP14. 2 short to JP14. 3 Under the condition of HIALLNC VIO_SEL=0 , put the jumps on JP14 pin2/3 to select level shifter 1. 8V voltage supply. Keep JP14 open for HiLoNC3GPS.
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
22
3. 13 PCM level shifter JP9. 1 short to JP9. 2 Select 2. 8V voltage level for PCM level shift. This setting is for HiLoNC3GPS module.
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
23
3. 14 SDIO(HiLoNC3GPS)/UART0(HIALLNC) SW5 Due to HiLoNC3GPS and HIALLNC share some pads but for different function, SW5 configuration is mandatory. [. . . ] Keep JP14 open for HiLoNC3GPS.
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
22
3. 13 PCM level shifter JP9. 1 short to JP9. 2 Select 2. 8V voltage level for PCM level shift. This setting is for HiLoNC3GPS module.
External document | URD1 OTL 5696. 1-025 72772 ed 01 | 22 September 2011
This document and the information contained are Sagemcom property and shall not be copied or disclosed to any third party without Sagemcom prior written authorization
23
3. 14 SDIO(HiLoNC3GPS)/UART0(HIALLNC) SW5 Due to HiLoNC3GPS and HIALLNC share some pads but for different function, SW5 configuration is mandatory. The silkscreen on PCB also indicates the setting for HiLoNC3GPS and HIALLNC. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE SAGEM TGR 350SG
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SAGEM TGR 350SG will begin.