User manual SAUNIER DUVAL SD 30E
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAUNIER DUVAL SD 30E. We hope that this SAUNIER DUVAL SD 30E user guide will be useful to you.
Manual abstract: user guide SAUNIER DUVAL SD 30E
Detailed instructions for use are in the User's Guide.
[. . . ] 221873B. 07. 01
Instructions for Use Installation and Servicing
To b e l e f t w i t h t h e u s e r
7086
SD 30e
G. C. 47-920-16
Fanned Flue Combination Boiler
This is a Cat I2H Appliance
The instructions consist of three parts, User, Installation and Servicing Instructions, which include the Guarantee Registration Card. The instructions are an integral part of the appliance and must, to comply with the current issue of the Gas Safety (Installation and Use) Regulations, be handed to the user on completion of the installation.
Guarantee Registration
Thank you for installing a new Saunier Duval appliance in your home. Saunier Duval appliances' are manufactured to the very highest standard so we are pleased to offer our customers' a Comprehensive First Year Guarantee. [. . . ] The mains cable outer insulation must not be cut back external to the plug.
CONNECTION BLOCK
RED LINK
CABLE CLAMP
GROMMET
R2 R1
N L
9. 3 Frost Thermostat
If the installation requires protection by a "frost thermostat", connect a single pole type, to the appropriate terminals of the connector. Keep all cables away from hot surfaces.
SCREW (2)
MAINS CABLE
9. 4 Electrical Test
Carry out preliminary electrical system checks as below: 1. Refit the control fascia.
Diagram 9. 2
221873B
20
7024
6964
9. 1 Supply Cable Connection
9 Electrical Connections
EXTERNAL CLOCK
RED LINK. REMOVE WHEN CONNECTING ANY HEATING SYSTEM CONTROLS (L) TO BOILER 5 WAY TERMINAL BLOCK
INTEGRAL CLOCK
TO BOILER
5 WAY TERMINAL BLOCK
(L) (N) (R1) (R2)
(N)
(R1)
(R2) RED LINK
SWITCH CONTACTS CLOCK JUNCTION BOX TIME CONTROL 3 AMP FUSE E
MAINS POTENTIAL FROST STAT.
L JUNCTION BOX
230V~50Hz DOUBLE PERMANENT MAINS POLE N SUPPLY ISOLATOR
230V~50Hz FROST STAT. NO ROOM STAT.
INTEGRAL CLOCK
3 AMP FUSE DOUBLE POLE ISOLATOR 230V~50Hz PERMANENT MAINS SUPPLY L (L) ROOM THERMOSTAT N E FROST THERMOSTAT (N)
TO BOILER
5 WAY TERMINAL BLOCK
(R1)
(R2)
MAINS POTENTIAL FROST STAT.
ELECTRICITY SUPPLY CONNECTIONS
INTEGRAL CLOCK
TO BOILER
JUNCTION BOX 3 AMP FUSE E
MAINS POTENTIAL ROOM STAT.
5 WAY TERMINAL BLOCK RED LINK. REMOVE WHEN CONNECTING SYSTEM CONTROLS
(L)
(N)
(R1)
(R2) L MAINS POTENTIAL ROOM STAT.
230V~50Hz PERMANENT MAINS DOUBLE N SUPPLY POLE ISOLATOR
JUNCTION BOX 3 AMP FUSE L DOUBLE POLE ISOLATOR E 230V~50Hz PERMANENT MAINS N SUPPLY
230V~50Hz 230V~50Hz FROST STAT. REMOVE WHEN CONNECTING SYSTEM CONTROLS
INTEGRAL CLOCK
TO BOILER
5 WAY TERMINAL BLOCK
230V~50Hz ROOM STAT. NO FROST STAT.
(L) (N) (R1) (R2)
INTEGRAL CLOCK
TO BOILER 230V~50Hz POTENTIAL FROST STAT.
5 WAY TERMINAL BLOCK
(L)
(N)
(R1)
(R2) JUNCTION BOX 3 AMP FUSE E
230V~50Hz POTENTIAL ROOM STAT.
3 AMP FUSE
E 230V~50Hz PERMANENT MAINS SUPPLY POTENTIAL FREE ROOM STAT. REMOVE WHEN CONNECTING SYSTEM CONTROLS L
L
DOUBLE N POLE ISOLATOR
230V~50Hz DOUBLE PERMANENT MAINS POLE N SUPPLY ISOLATOR
RED LINK. NO FROST STAT.
230V~50Hz ROOM STAT.
230V~50Hz FROST STAT.
Diagram 9. 3
21
221873B
7100
10 Commissioning
Please ensure the "Benchmark" logbook is completed and left with the user. Check the operation of the safety valve by turning the safety valve knob in the direction of the arrow. Lower the pressure to the initial cold fill design pressure, refer to Table 1. Position the set pointer on the boiler pressure gauge at this pressure also. Refit inner case front.
10. 1 Filling Domestic Water Circuit
Check that the boiler is isolated from the electrical supply, at the external isolator. Fully open the domestic water supply stop cock or valve in the supply to the boiler. Open the inlet domestic water isolation valve, lever in line with the valve body, see diagram 6. 1. Check for water soundness of the whole domestic water system and boiler.
10. 3 Preparation for Lighting
Isolate the boiler from the mains electrical supply at the external isolator. Turn on the gas service cock, slot in line with the length of the cock. Loosen the burner pressure test point screw and connect a suitable pressure gauge, see diagram 10. 1.
10. 2 Filling the Heating System
Open the two central heating isolating valves, levers in line with the valve body, see diagram 6. 1. Flush, fill and vent the system refer to Section 4. 8 "Filling Sealed Systems". SEVERAL COMPONENTS OPERATE ON MAINS VOLTAGE AND WITH THE OUTER CASE REMOVED, LIVE COMPONENTS BECOME EXPOSED. Operate button "J" between "L" summer and "K" winter to ensure that water flows through all parts of the boiler and air is not trapped in the boiler internal bypass.
10. 4 Burner Pressure - Hot Water
Connect the electrical supply; the pump will operate for about 30 seconds, then the pump will stop. [. . . ] Remove the plate to plate heat exchanger, refer to Section 14. 23.
14. 24 Expansion Vessel
Before starting refer to Section 11. Renewal of the expansion vessel requires the boiler to be removed from the wall. As an alternative, a separate expansion vessel of the same specification may be connected as close as possible to the boiler, leaving the original in position, refer to the Installation Instructions. Disconnect the boiler water connection union nuts at the front of the isolating valves, see 6. 1.
SECURING PIN 1 RETAINING CLIP DIVERTER SWITCH LEFT HAND ELECTRICAL PLUG PRESSURE DIFFERENTIAL MICRO SWITCH SECURING PIN 2 and 3
PUMP
RIGHT HAND
DOMESTIC HOT WATER THERMISTOR
SECURING PIN 4 and 5
FILTER
Diagram 14. 18
221873B
37
7077
7019a
GAS CONTROL VALVE MULTI PIN CONNECTOR
LOW WATER PRESSURE SWITCH
SECURING PIN 6 DOMESTIC HOT WATER MICRO SWITCH
HYDRO BLOCK ASSEMBLY PLUG
14 Replacement of Parts
Disconnect the gas service cock union. [. . . ]