User manual SONY ICD-BP150

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SONY ICD-BP150. We hope that this SONY ICD-BP150 user guide will be useful to you.


SONY ICD-BP150 : Download the complete user guide (1229 Ko)

You may also download the following manuals related to this product:

   SONY ICD-BP150 (1261 ko)
   SONY ICD-BP150 (1259 ko)
   SONY ICD-BP150 (1249 ko)
   SONY ICD-BP150 (1235 ko)
   SONY ICD-BP150 (1264 ko)
   SONY ICD-BP150 annexe 1 (1273 ko)
   SONY ICD-BP150 annexe 1 (1260 ko)
   SONY ICD-BP150 annexe 1 (1233 ko)
   SONY ICD-BP150 annexe 2 (1233 ko)
   SONY ICD-BP150 annexe 3 (1233 ko)
   SONY ICD-BP150 DATASHEET (236 ko)
   SONY ICD-BP150 DIGITAL VOICE EDITOR 2 INSTRUCTIONS (166 ko)

Manual abstract: user guide SONY ICD-BP150

Detailed instructions for use are in the User's Guide.

[. . . ] 3-240-358-12 (1) IC Recorder Operating Instructions Owner's Record The model number is located at the rear and the serial number is located inside the battery compartment. Refer to these numbers whenever you call upon your Sony dealer regarding this product. ICD-BP150 Serial No. ICD-BP150 2002 Sony Corporation For the customers in the United States INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. [. . . ] or > to select the day of the week. · to record at the same time every day Press . or > to select "DAILY" and press NxPLAY/STOP. 3 Set the recording start time. 1 Press . or > to select the minute digits and press NxPLAY/STOP. "END" is displayed for one second, and then the hour digits of the recording end will flash in the display window. 4 5 6 Repeat Step 3 to set the recording end time. or > to select "SP" or "LP" and press NxPLAY/STOP. Press MENU to exit the menu mode. The display will return to normal display and " " is displayed. Other Functions At the set time, recording starts automatically. When the recording ends, the unit will stop automatically at the beginning of the newly recorded message. Continued 33GB Starting Recording at a Desired Time -- Timer Recording (continued) To stop the timer recording Press xSTOP. To change the timer setting Press . or > in Step 2, 3 or 4 on page 33 to change the year, month, day or time and press NxPLAY/STOP. To cancel the timer recording setting Select "OFF" in Steps 1-3 on page 32 and press NxPLAY/STOP. Notes · You cannot set the timer to record more than one message. · When the timer recording starts, the recording mode selected in Step 5 is automatically selected. When the recording ends, the recording mode is reset to the initial setting. · Make sure that the remaining recording time is long enough for the timer recording. You cannot set the timer if the length of the timer recording exceeds the remaining recording time. However, in the case of recording once a week or everyday, you can set the timer if the remaining recording time is longer than the first recording and for the second or later recording, timer recording stops when there is no more remaining time on the IC recorder. · If 99 messages have been recorded in the selected folder or the memory is full, timer recording will not start. · If the timer is set to start recording before 23:59 and to end recording after 0:00, the recording will stop the next day. · If the timer start time comes during alarm playback, playback will stop and the timer recording starts. · When the timer recording start time comes during operation other than recording, the operation stops and the timer recording starts. When the timer recording start time comes during recording, the recording continues and the timer recording will not start. 34GB Playing Back a Message at a Desired Time with an Alarm You can sound an alarm and start playback of a selected message at a desired time. You can have the message played back at a desired date, once every week, or the same time everyday. You can also sound the alarm without playing back a message. . /> NxPLAY/STOP MENU 1 2 Select the message you wish to play back. (See Steps 1 and 2 on page 16. ) Press MENU. "ALARM OFF" will be displayed. ) Note The alarm cannot be set if the clock has not been set or no message has been recorded in the selected folder. Other Functions 3 Set the alarm setting to ON. 1 Press Nx. 3 Press Nx. Continued 35GB Playing Back a Message at a Desired Time with an Alarm (continued) 4 Set the alarm date. · to play back on a desired date 1 Press Nx while 2 Press . 3 Select the month and day digits in the same way. · to play back once a week Press . [. . . ] ·You cannot erase an index to combine messages of different modes. ·If you do not set date and time, you cannot make alarm or time recording setting. ·When there are already 99 messages in the selected folder or the remaining memory of the IC recorder is short, you cannot add an index. Wait until the message disappears before starting operation. "BACK-D" "NO ERASE" "NO DATA" "SET DATE" "ID FULL" "FULL" "ACCESS" For the error messages of the "Digital Voice Editor", please refer to the online Help files. 60GB System limitations There are some system limitations of the IC recorder. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SONY ICD-BP150




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SONY ICD-BP150 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.