User manual WHIRLPOOL AMB 867/G INSTRUCTION FOR USE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL AMB 867/G. We hope that this WHIRLPOOL AMB 867/G user guide will be useful to you.


WHIRLPOOL AMB 867/G INSTRUCTION FOR USE: Download the complete user guide (440 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL AMB 867/G MODE D'EMPLOI (444 ko)
   WHIRLPOOL AMB 867/G GEBRUIKSAANWIJZING (436 ko)
   WHIRLPOOL AMB 867/G BEDIENUNGSANLEITUNG (434 ko)
   WHIRLPOOL AMB 867/G INSTRUZIONI PER L'USO (443 ko)
   WHIRLPOOL AMB 867/G LIBRO DE INSTRUCCIONES (442 ko)

Manual abstract: user guide WHIRLPOOL AMB 867/GINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTIONS FOR USE SINGLE SPLIT AIR CONDITIONER WITH GREEN GAS AND WITH GAS R22 PREPARATION BEFORE USE SAFETY PRECAUTIONS IDENTIFICATION OF PARTS REMOTE CONTROL OPERATION INSTRUCTIONS MAINTENANCE TROUBLESHOOTING PROTECTION INSTALLATION INSTRUCTIONS ELECTRICAL CONNECTION CLASSIC RANGE R22 GREEN RANGE Disposal of old appliances • This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. [. . . ] 1 hour Decrease by 1°C Decrease by START Decrease by 1 hour STOP *: In cooling mode, if room temperature is 26°C or above, set temperature will not change. **: Heating is NOT available for cooling only air conditioner. 146 MAINTENANCE Appliance maintenance Unplug from the power supply Stop the appliance before unplugging. • To remove the front panel pull it outwards as shown in the figure (a) Wipe with a soft, dry cloth Use lukewarm water (below 40°C) to clean the appliance when it is very dirty. Never use volatile substances such as gasoline or polishing powder to clean the unit. Refit and close the front panel • Refit and close the front panel by pushing it downwards as shown in the figure (b). Clean the air filter It is advisable to clean the air filter after approx. Replace the filter in its original position after cleaning If the filter is very dirty, clean it with a solution of lukewarm water and neutral detergent, then dry it in the air. IMPORTANT: Clean the air filter every two weeks when the air conditioner is operated in a dusty environment. TROUBLESHOOTING Trouble Does not run Analysis • • • • • • • • • • • • • • Is the protection device or fuse blown?If there is a strong interference (from excessive static electricity discharge, power supply voltage abnormality) presents, operation will be abnormal. In this case, unplug from the power supply and plug in after 2-3 seconds. Caused by the flow of refrigerant in the air conditioner, not a fault. Caused by the expansion or contraction of the front panel because of temperature changing, not a fault. Mist appears when the room air becomes very cold as during operation in “COOLING” or “DRY” mode. The indicator will turn off within ten minutes and return to heating mode. No cool or warm air Ineffective control Does not operate immediately Peculiar smell A sound of running-water A “pixi” sound can be heard Spray mist from the outlet The compressor indicator (red) lights up constantly, and the indoor fan stops. 147 PROTECTION Operating condition The protective device may trip and stop the appliance in the cases listed below. Outdoor air temperature is over 24°C *HEATING Outdoor air temperature is below -7°C Room temperature is over 27°C COOLING DRY Outdoor air temperature is over* 43°C Room temperature is below 21°C Room temperature is below 18°C *For Tropical (T3) Climate condition models, the temperature point is 52°C instead of 43°C. If the air conditioner runs in “COOLING” or “DRY” mode with door and/or window open when relative humidity is higher than 80%, dew will drip down from the outlet. Features of protection device • The protection device will trip in the following cases: - Restarting the unit at once after operation stops or changing mode during operation, you need to wait 3 minutes. - After connecting to power supply and turning on the appliance immediately, there may be a delay of 20 seconds before it starts to operate. - If all operation has stopped, press ON/OFF button again to restart, Timer should be set again if it has been cancelled. Noise pollution • Install the air conditioner in a place that can bear its weight in order to operate more quietly. • Install the outdoor unit in a place where the air discharged and the operating noise do not annoy your neighbours. • Do not place an obstacle in front of the outlet of the outdoor unit as it may affect the air conditioner operation and increase the noise level. HEATING mode features Preheating 2-5 minutes are necessary to preheat the evaporator at the beginning of HEATING operation, so that cold air is not discharged. Defrosting In HEATING mode the appliance will defrost automatically to raise efficiency. After defrosting completes, it returns to HEATING mode automatically. Note: Heating is NOT available for cooling only air conditioner models. 148 INSTALLATION INSTRUCTIONS Distance from ceiling should be over 50 mm Distance from wall should be over 50 mm Installation diagram Distance from the wall should be over 50 mm Distance from floor should be over 2500 mm Air intake distance from the wall should be over 250 mm Air intake distance from the wall should be over 250 mm Air sho outle uld t di be stan ove ce r 5 from 00 mm the wa ll Over 250 mm NOTE: The figure above is only a simple presentation of the unit, it may not match the external appearance of the unit you purchased. Installation must be performed in accordance with the national wiring standards by authorised personnel only. 149 Select the best location Location for Installing the Indoor Unit • Where there is no obstacle near the air outlet and air can easily be blown to every corner. • Observe the required distance from ceiling and wall according to the wiring diagram. [. . . ] If this is not possible, connect the appliance to a double-pole switching device with contact distance of at least 3 mm placed in an accessible position even after installation. • Please pay more attention to the details of 2-way and 3-way valve. Service valve: 7/16 inch for R410A model; and 1/4 inch for R22 and R407C. Diameter of hexagon (inward): 4mm for R410A model; 5mm for R407C and R22. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AMB 867/G




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AMB 867/G will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.