Manual abstract: user guide WHIRLPOOL WGD85HEFCINSTALLATION GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] Com
INSTALLATION NOTES
Date of purchase:___________________________________ Date of installation:_________________________________ Installer:__________________________________________ Model number:_____________________________________ Serial number:_____________________________________
NOTES CONCERNANT L’INSTALLATION
Date d’achat:______________________________________ Date d’installation:__________________________________ Installateur:_______________________________________ Numéro de modéle:_________________________________ Numéro de série:___________________________________
W10868945A W10868946A-SP
DRYER SAFETY
2
3
INSTALLATION REQUIREMENTS
TOOLS AND PARTS
Gather the required tools and parts before starting installation. Tools needed for gas installations:
Tools needed for all installations:
8" or 10" pipe wrench 8" or 10" adjustable wrench (for gas connections)
Flat-blade screwdriver
#2 Phillips screwdriver
Pipe-joint compound resistant to LP gas ¼" and 5/16" nut driver (recommended) Level
Parts supplied (all models):
Tape measure
Pliers
Leveling legs (4)
Parts supplied (steam models):
Utility knife
Tin snips (new vent installations) “Y” connector 2' (0. 6 m) inlet hose
Caulking gun and compound (new vent installations)
Adjustable wrench that opens to 1" (25 mm) or hex-head socket wrench Rubber washer Parts package is located in dryer drum. NOTE: Do not use leveling legs supplied with dryer if installing with a pedestal or a stack kit. [. . . ] Burner information is located on the rating plate in the door well of your dryer. If this information does not agree with the type of gas available, contact your dealer or call the phone numbers referenced in the “Assistance or Service” section of your Use and Care Guide. Gas shut-off valve
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualified technician. No attempt shall be made to convert the appliance from the gas specified on the model/serial rating plate for use with a different gas without consulting your gas company. 8
GAS SUPPLY CONNECTION REQUIREMENTS ■■ Use an elbow and a 3⁄8" flare x 3⁄8" NPT adapter fitting
INSTALL LEVELING LEGS
between the flexible gas connector and the dryer gas pipe, as needed to avoid kinking. ■ This dryer must be connected to the gas supply line with a listed flexible gas connector that complies with the standard for connectors for gas appliances, ANSI Z21. Your connection may be different, according to supply line type, size, and location. ■ The length of flexible metal vent used must be included
in the overall vent system design as shown in the “Vent System Charts. Open valve
NOTE: If using an existing vent system, clean lint from entire
Open shut-off valve in supply line; valve is open when handle is parallel to gas pipe. Length of the system and make sure exhaust hood is not plugged with lint. 10
Exhaust hoods:
■■ An exhaust hood should cap the vent to keep rodents and
Plan Vent System
Choose your exhaust installation type Recommended exhaust installation:
B A F G C D E
insects from entering the home. ■ Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes, or snow). Exhaust outlet
Acceptable Style:
Angled Hood
Elbows:
■■ 45° elbows provide better airflow than 90° elbows. ■ Exhaust vent must not be connected or secured with screws
Optional exhaust installations:
This dryer can be converted to exhaust out the right side, left side (all models except long vent), or through the bottom. If you prefer, you may contact your local dealer to have the dryer converted. Or other fastening devices that extend into interior of duct and catch lint. Bottom exhaust installation
C
11
Special provisions for mobile homes:
Exhaust vent must be securely fastened to a noncombustible portion of mobile home and must not terminate beneath the mobile home. 6 m)
0 1 2 3 4
To determine if your model has a long vent system, refer to the type code located on the serial number plate in the inner door well. ■ When using elbows or making turns, allow as much room
as possible. (305 mm)
Determine vent length and elbows needed for best drying performance:
■■ Use the “Vent System Charts” on the next page to determine
Install exhaust hood and use caulking compound to seal exterior wall opening around exhaust hood. NOTE: Do not use vent runs longer than those specified in “Vent System Charts. Exhaust systems longer than those specified will: ■■ Shorten life of dryer. [. . . ] Insert the tabs on the hinge into the mounting slot and slide down to engage the top tab. Reinstall inner door assembly
Bottom of door
Position the door with the inside of the door facing up. Remove inner door from outer door
IMPORTANT: If the protective film has not yet been removed from the dryer, peel the film from the dryer door before proceeding. Using a T25® screwdriver, remove the 4 screws securing the door hinge to the dryer and lift up and out to remove the door. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WGD85HEFC
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WGD85HEFC will begin.